Safety data sheet Océ TDS400 printer and scanner
PRODUCT SAFETY DATA SHEET
Océ-USA, Inc.
|
|
|
|
|
|
|
| Number | |||
|
|
|
|
|
|
|
| Date |
| August 2000 | |
|
|
|
|
|
|
|
|
|
|
|
|
Model |
| Océ TDS400 |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
Description |
| Multifunction device, instant copying/printing, consisting of an electrophotographic printer, | |||||||||
|
| console model, plain paper, organic photoconductive drum, powder toner and a free standing | |||||||||
|
| scanner. |
|
|
|
|
|
|
|
|
|
Max. process speed |
| 3 m/min |
|
|
|
|
|
|
|
|
|
Dimensions | Width | Engine |
| Scanner | Controller |
| Monitor (17”) | ||||
1352 | mm |
| 1240 | mm | 206 | mm |
| 299 | mm | ||
| Depth | 899 | mm |
| 615 | mm | 437 | mm |
| 410 | mm |
| Height | 1251 | mm |
| 1105 | mm | 444 | mm |
| 409 | mm |
Weight |
| 175 | kg |
| 65 | kg | 15 | kg |
| 15 | kg |
|
| 10 kg (extra roll) |
|
|
|
|
|
|
|
| |
Voltage |
| 100/115/230 | V | 100/115/230 | V | 100/230 | V | V | |||
Frequency |
| 50/60 | Hz |
| Hz | Hz |
| Hz | |||
| 15/15/7,5 | A | 1,1/1,1/0,7 | A | 0,9 | A |
|
|
| ||
| 20/20/10 | A | 1,6/1,6/0,8 | A | 6/3 | A |
| 1,4 | A | ||
Power consumption, stand by | 30 | W | 27 |
| W |
|
|
|
|
| |
Power consumption, operation | 1,5 | kW | 1 | 40 | W | 40 | W |
| 70 | W | |
EPA ENERGY STAR ® |
|
|
|
|
|
|
|
|
|
|
|
* Power consumption sleep mode | 52 W (total system) |
|
|
|
|
|
|
|
| ||
Mains connection |
| Cables with plug |
|
|
|
|
|
|
|
| |
Safety class |
| I | (IEC 536) Protective earth connection |
|
|
|
| ||||
Protection class |
| IP 20 | (IEC 529) |
|
|
|
|
|
|
| |
Sound pressure level | Standby |
|
| In operation |
|
|
|
| |||
24 dB(A) |
|
| main body 54 dB(A) |
|
|
|
| ||||
(at bystander position) |
|
|
| impulse | Li = 4 dB(A) |
|
|
|
| ||
Sound power level |
| 41 dB(A) |
|
| main body 63 dB(A) |
|
|
|
| ||
Radio interference |
| Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A. |
| ||||||||
Radiation |
| Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH) |
| ||||||||
Heat emission |
| Standby 182 W; at continuous operation 1,8 kW |
|
|
|
| |||||
Ozone emission |
| 0,04 mg/min at continuous operation |
|
|
|
|
|
| |||
Room volume |
| Recommendation: min. 25 m3 |
|
|
|
|
|
|
| ||
Room ventilation |
| Recommendation: min.12,5 m3/h (natural ventilation) |
|
|
|
| |||||
Use simulation at random | With a room volume and ventilation as recommended and a daily volume of 150 m (much | ||||||||||
operation |
| more than average) the use simulation at random operation gives the following ozone |
| ||||||||
|
| concentrations: |
|
|
|
| mg/m3 |
|
|
| |
|
| - Time weighted average |
|
| 0,01 |
| (0,005 | ppm) | |||
|
| - Peak |
|
|
|
| 0,002 | mg/m3 |
| (0,001 | ppm) |
|
| Threshold Limit Value/Occupational Exposure Limit | mg/m3 |
|
|
| |||||
|
| (Time Weighted Average) for ozone |
| 0,2 |
| (0,1 | ppm) | ||||
|
| Odour Perception Limit for ozone |
| 0,04 | mg/m3 |
| (0,02 | ppm) | |||
Consumables |
| Océ OPC Drum (Océ Safety Data Sheet |
|
|
|
| |||||
|
| Océ B5 Toner (Océ Safety Data Sheet |
|
|
|
|
| ||||
|
| Océ D5 Developer (Océ Safety Data Sheet |
|
|
|
| |||||
|
| Océ Copying Materials. |
|
|
|
|
|
|
| ||
|
| This apparatus is suitable for processing recycling paper which complies with the |
| ||||||||
|
| requirements of ENV 12281. |
|
|
|
|
|
|
| ||
Additional safety information | The ozone filter does not have to be replaced to keep the ozone concentration in the |
| |||||||||
|
| workplace below 0,04 mg/m3 (i.e. the life of the filter equals that of the apparatus). |
| ||||||||
| Listed according to standard UL 1950 and | EPA ENERGY STAR ® |
| ||||||||
|
|
|
|
| LISTED 927F |
|
|
|
|
| |
|
|
|
|
| INFORMATION |
|
|
|
|
| |
|
|
|
|
| TECHNOLOGY |
|
|
|
|
| |
|
|
|
|
| EQUIPMENT |
|
|
|
|
| |
|
|
|
|
| E 69871 |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Copyright © 2000
The content of this safety data sheet is subject to the disclaimer of liability on page 224 of this manual.
226 | Océ TDS400 User Manual |