Safety data sheet Océ TDS400 printer and scanner
PRODUCT SAFETY DATA SHEET
Océ-USA,  Inc.
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | Number | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | Date | 
 | August 2000 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Model | 
 | Océ TDS400 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | |||||||||
| Description | 
 | Multifunction device, instant copying/printing, consisting of an electrophotographic printer, | |||||||||
| 
 | 
 | console model, plain paper, organic photoconductive drum, powder toner and a free standing | |||||||||
| 
 | 
 | scanner. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Max. process speed | 
 | 3 m/min | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Dimensions | Width | Engine | 
 | Scanner | Controller | 
 | Monitor (17”) | ||||
| 1352 | mm | 
 | 1240 | mm | 206 | mm | 
 | 299 | mm | ||
| 
 | Depth | 899 | mm | 
 | 615 | mm | 437 | mm | 
 | 410 | mm | 
| 
 | Height | 1251 | mm | 
 | 1105 | mm | 444 | mm | 
 | 409 | mm | 
| Weight | 
 | 175 | kg | 
 | 65 | kg | 15 | kg | 
 | 15 | kg | 
| 
 | 
 | 10 kg (extra roll) | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Voltage | 
 | 100/115/230 | V | 100/115/230 | V | 100/230 | V | V | |||
| Frequency | 
 | 50/60 | Hz | 
 | Hz | Hz | 
 | Hz | |||
| 
 | 15/15/7,5 | A | 1,1/1,1/0,7 | A | 0,9 | A | 
 | 
 | 
 | ||
| 
 | 20/20/10 | A | 1,6/1,6/0,8 | A | 6/3 | A | 
 | 1,4 | A | ||
| Power consumption, stand by | 30 | W | 27 | 
 | W | 
 | 
 | 
 | 
 | 
 | |
| Power consumption, operation | 1,5 | kW | 1 | 40 | W | 40 | W | 
 | 70 | W | |
| EPA ENERGY STAR ® | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| * Power consumption sleep mode | 52 W (total system) | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| Mains connection | 
 | Cables with plug | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Safety class | 
 | I | (IEC 536) Protective earth connection | 
 | 
 | 
 | 
 | ||||
| Protection class | 
 | IP 20 | (IEC 529) | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Sound pressure level | Standby | 
 | 
 | In operation | 
 | 
 | 
 | 
 | |||
| 24 dB(A) | 
 | 
 | main body 54 dB(A) | 
 | 
 | 
 | 
 | ||||
| (at bystander position) | 
 | 
 | 
 | impulse | Li = 4 dB(A) | 
 | 
 | 
 | 
 | ||
| Sound power level | 
 | 41 dB(A) | 
 | 
 | main body 63 dB(A) | 
 | 
 | 
 | 
 | ||
| Radio interference | 
 | Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A. | 
 | ||||||||
| Radiation | 
 | Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH) | 
 | ||||||||
| Heat emission | 
 | Standby 182 W; at continuous operation 1,8 kW | 
 | 
 | 
 | 
 | |||||
| Ozone emission | 
 | 0,04 mg/min at continuous operation | 
 | 
 | 
 | 
 | 
 | 
 | |||
| Room volume | 
 | Recommendation: min. 25 m3 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| Room ventilation | 
 | Recommendation: min.12,5 m3/h (natural ventilation) | 
 | 
 | 
 | 
 | |||||
| Use simulation at random | With a room volume and ventilation as recommended and a daily volume of 150 m (much | ||||||||||
| operation | 
 | more than average) the use simulation at random operation gives the following ozone | 
 | ||||||||
| 
 | 
 | concentrations: | 
 | 
 | 
 | 
 | mg/m3 | 
 | 
 | 
 | |
| 
 | 
 | - Time weighted average | 
 | 
 | 0,01 | 
 | (0,005 | ppm) | |||
| 
 | 
 | - Peak | 
 | 
 | 
 | 
 | 0,002 | mg/m3 | 
 | (0,001 | ppm) | 
| 
 | 
 | Threshold Limit Value/Occupational Exposure Limit | mg/m3 | 
 | 
 | 
 | |||||
| 
 | 
 | (Time Weighted Average) for ozone | 
 | 0,2 | 
 | (0,1 | ppm) | ||||
| 
 | 
 | Odour Perception Limit for ozone | 
 | 0,04 | mg/m3 | 
 | (0,02 | ppm) | |||
| Consumables | 
 | Océ OPC Drum (Océ Safety Data Sheet  | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | Océ B5 Toner (Océ Safety Data Sheet  | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | Océ D5 Developer (Océ Safety Data Sheet  | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | Océ Copying Materials. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | This apparatus is suitable for processing recycling paper which complies with the | 
 | ||||||||
| 
 | 
 | requirements of ENV 12281. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| Additional safety information | The ozone filter does not have to be replaced to keep the ozone concentration in the | 
 | |||||||||
| 
 | 
 | workplace below 0,04 mg/m3 (i.e. the life of the filter equals that of the apparatus). | 
 | ||||||||
| 
 | Listed according to standard UL 1950 and  | EPA ENERGY STAR ® | 
 | ||||||||
| 
 | 
 | 
 | 
 | 
 | LISTED 927F | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | INFORMATION | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | TECHNOLOGY | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | EQUIPMENT | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | E 69871 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
Copyright © 2000 
The content of this safety data sheet is subject to the disclaimer of liability on page 224 of this manual.
| 226 | Océ TDS400 User Manual | 