PNU

 

Description

Value range

No. indices

See

 

 

 

 

[Unit]

Factory

Change

 

 

 

 

Steps

setting

(Access /

 

 

 

 

 

Type

Status)

 

r022

 

Display of torque setpoint before torque limitation

-400.0 to 400.0

Ind: None

P052 = 3

 

 

 

[%]

Type: I2

 

 

(G160)

 

Steps: 1 = 0.1% of rated motor torque (=rated motor armature current

0.1% (see column on

 

 

 

 

(P100) * magnetic flux at rated motor field current (P102))

left)

 

 

 

 

 

 

 

 

 

 

 

-200.00 to 199.99

 

 

 

r023

 

Display of speed controller setpoint/actual value deviation

Ind: None

P052 = 3

 

 

 

 

[%]

Type: I2

 

 

(G152)

 

 

0.01%

 

 

 

r024

 

Display of actual speed value from pulse encoder

-200.00 to 199.99

Ind: None

P052 = 3

 

 

 

 

[%]

Type: I2

 

 

(G145)

 

 

0.01%

 

 

 

r025

 

Display of actual speed controller value

-200.0 to 199.99

Ind: None

P052 = 3

 

 

 

 

[%]

Type: I2

 

 

(G151)

 

 

0.01%

 

 

 

r026

 

Display of speed controller setpoint

-200.0 to 199.99

Ind: None

P052 = 3

 

 

 

 

[%]

Type: I2

 

 

(G152)

 

 

0.01%

 

 

 

r027

 

Display of ramp-function generator output

-200.00 to 199.99

Ind: None

P052 = 3

 

 

 

 

[%]

Type: I2

 

 

(G136)

 

 

0.01%

 

 

 

r028

 

Display of ramp-function generator input

-200.00 to 199.99

Ind: None

P052 = 3

 

 

 

 

[%]

Type: I2

 

 

(G136)

 

 

0.01%

 

 

 

r029

 

Display of main setpoint before limitation

-200.00 to 199.99

Ind: None

P052 = 3

 

 

 

 

[%]

Type: I2

 

 

(G135)

 

 

0.01%

 

 

 

r034

 

Display of firing angle (field)

0.00 to 180.00

Ind: None

P052 = 3

 

(G166)

 

 

[degrees]

Type: O2

 

 

 

 

0.01degrees

 

 

 

r035

 

Display of field current controller actual value

0.0 to 199.9

Ind: None

P052 = 3

 

(G166)

 

 

[% of P102]

Type: O2

 

 

 

 

0.1% of P102

 

 

 

r036

 

Display of field current controller setpoint

0.0 to 199.9

Ind: None

P052 = 3

 

(G166)

 

 

[% of P102]

Type: O2

 

 

 

 

0.1% of P102

 

 

 

r037

 

Display of actual EMF value

-1500.0 to 1500.0

Ind: None

P052 = 3

 

(G165)

 

 

[V]

Type: I2

 

 

 

 

0.1V

 

 

 

 

 

 

 

 

 

r038

 

Display of actual armature voltage value

-1500.0 to 1500.0

Ind: None

P052 = 3

 

 

 

 

[V]

Type: I2

 

 

 

 

 

0.1V

 

 

 

r039

 

Display of EMF setpoint

0.0 to 1500.0

Ind: None

P052 = 3

 

(G165)

 

This parameter displays the EMF setpoint which is applied as the control

[V]

Type: O2

 

 

 

0.1V

 

 

 

 

 

quantity in the field-weakening range.

 

 

 

 

 

 

 

 

 

 

 

This value is calculated from:

 

 

 

 

 

 

Umotorrated Imotorrated * RA (= P101 – P100 * P110)

 

 

 

SIEMENS Energy & Automation

10-9

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 130