PNU

 

Description

Value range

No. indices

See

 

 

 

 

[Unit]

Factory

Change

 

 

 

 

Steps

setting

(Access /

 

 

 

 

 

Type

Status)

 

P746

 

Source for enabling of "Main actual value" analog input

All binector numbers

Ind: None

P052 = 3

*

 

Selection of binector to control enabling of the analog input ("1" state =

1

FS=1

P051 = 40

 

 

 

 

Type: L2

Offline

 

(G113)

 

enabled)

 

 

 

 

 

 

 

 

 

 

 

 

0 = binector B0000

 

 

 

 

 

 

1 = binector B0001

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

10.38 Analog outputs

(see also Section 8, Sheets G115 and G116 of Operating Instructions 6RX1700-0AD**)

Analog output terminals 12 / 13 (actual current display)

P749

Control word for terminal 12 (actual current display)

0 to 3

Ind: None

P052 = 3

*

0

Output with correct sign

1

FS=0

P051 = 40

 

 

Type: O2

Online

(G115)

 

(positive voltage: Current in torque direction MI)

 

 

 

 

 

 

(negative voltage: Current in torque direction MII)

 

 

 

 

 

 

 

 

 

1

Output of absolute value (positive voltage only)

 

 

 

 

2

Output with sign, inverted

 

 

 

 

 

(positive voltage: Current in torque direction MII)

 

 

 

 

 

(negative voltage: Current in torque direction MI)

 

 

 

 

3

Output of absolute value, inverted (negative voltage only)

 

 

 

 

 

 

 

 

 

Analog output terminals 14 / 15

P750

Source for output value at analog output 1

*

Selection of connector whose value is to applied to the analog output

 

(G115)

0 = connector K0000

 

1 = connector K0001

 

etc.

P751

Mode of signal injection at analog output 1

*

0 =

Injection of signal with correct sign

 

(G115)

1 =

Injection of absolute value of signal

2 =

Injection of signal with sign, inverted

 

 

3 =

Injection of absolute value of signal, inverted

 

 

 

 

P752

Filtering time for analog output 1

(G115)

 

 

 

 

P753

Normalization of analog output 1

(G115)

y [V ] = x

P753

100 %

 

 

x = Normalization input (corresponds to filtering output)

 

y = Normalization output (corresponds to output voltage at analog output

 

with offset = 0)

 

 

P754

Offset for analog output 1

(G115)

 

 

 

 

All connector numbers

1

0 to 3

1

0 to 10000 [ms] 1ms

-200.00 to 199.99 [V]

0.01V

-10.00 to 10.00 [V]

0.01V

Ind: None

P052

= 3

FS=0

P051

= 40

Type: L2

Online

 

 

 

Ind: None

P052

= 3

FS=0

P051

= 40

Type: O2

Online

 

 

 

Ind: None

P052

= 3

FS=0

P051

= 40

Type: O2

Online

Ind: None

P052

= 3

FS=10.00

P051

= 40

Type: I2

Online

 

 

 

Ind: None

P052

= 3

FS=0.00

P051

= 40

Type: I2

Online

Analog output terminals 16 / 17

P755

Source for output value at analog output 2

*

Selection of connector whose value is to applied to the analog output

 

(G115)

0 = connector K0000

 

1 = connector K0001

 

etc.

P756

Mode of signal injection at analog output 2

*

0 =

Injection of signal with correct sign

 

(G115)

1 =

Injection of absolute value of signal

2 =

Injection of signal with sign, inverted

 

 

3 =

Injection of absolute value of signal, inverted

 

 

P757

Filtering time for analog output 2

(G115)

 

 

All connector numbers

1

0 to 3

1

0 to 10000 [ms] 1ms

Ind: None

P052

= 3

FS=0

P051

= 40

Type: L2

Online

 

 

 

Ind: None

P052

= 3

FS=0

P051

= 40

Type: O2

Online

 

 

 

Ind: None

P052

= 3

FS=0

P051

= 40

Type: O2

Online

SIEMENS Energy & Automation

10-75

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 196
Image 196
Siemens 6RA70 specifications Analog outputs, 10-75