Siemens 6RA70 specifications 1180 1660 1680

Models: 6RA70

1 232
Download 232 pages 59.99 Kb
Page 28
Image 28

5.3 1180ADC, 1660ADC & 1680ADC Base Drive Panels, 3AC 460V, 1 & 4Q

Rated supply voltage armature

V

 

 

 

3 Phase

 

 

1)

 

 

 

 

 

460 (+10% / – 5%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated input current armature

A

1000

 

1401

 

 

1455

 

2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan type

 

V

 

 

 

3 Phase

 

 

 

 

 

 

 

 

460V

 

 

 

 

 

 

 

 

 

 

 

 

Air flow rate

ft3/min

 

824

 

 

 

 

Fan noise level

 

dBA

 

88

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated supply voltage field

V

 

 

 

1 Phase 460 (+10%)

 

 

 

 

 

 

 

 

 

 

 

 

Rated frequency

 

Hz

45 to 65 Hz self adapting (armature and field are

 

 

 

independent)

 

 

 

 

 

 

 

 

 

 

 

 

Rated DC voltage 2)

 

V

 

500

 

 

 

 

Rated DC armature current

A

1180

 

 

1660

 

 

1680

 

Overload capability 60s

7)

 

 

 

 

150% of rated DC current

 

 

 

 

 

 

 

 

 

 

Rated output @ 500 VDC

Hp

700

 

1000

 

 

1000

 

 

 

 

 

 

 

 

 

 

Rated output @ 240 VDC

Hp

350

 

500

 

 

500

 

 

 

 

 

 

 

 

 

 

Power loss at rated DC current

W

5540

 

7590

 

 

7280

 

(approximately)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated DC voltage field

 

V

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated DC field current

 

A

 

40

 

 

85

 

Operational ambient

 

°C

 

 

 

0 to 45 at Irated

 

 

temperature

 

 

 

 

 

fan-cooled 4)

 

 

Storage and transport

 

°C

 

 

 

– 25 to +70

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation altitude above sea level

 

1000 m at rated DC current

5)

 

 

 

 

 

Control stability

 

 

n = 0.006% of the rated motor speed, valid for pulse

 

 

 

encoder operation and digital setpoint

 

 

 

 

 

n = 0.1% of the rated motor speed, valid for analog

 

 

 

tachometer or analog setpoint 6)

 

 

Degree of protection

 

 

 

 

 

Open Chassis (IP00)

 

 

 

 

 

 

Dimensions

 

 

Refer to dimension drawings in Section 6

 

 

 

 

 

 

 

 

 

Weights (approx.)

 

Lbs.

725

 

755

 

 

760

 

 

 

 

 

 

 

 

 

 

 

 

Siemens Energy & Automation

5-3