10.32 Field reversal

(see also Section 9 of Operating Instructions 6RX1700-0AD**)

P580

Source for selection of "Direction of rotation reversal using field

All binector numbers

Ind: 2

P052 = 3

*

reversal”

 

1

FS=0

P051 = 40

BDS

Selection of binector to control the "Direction of rotation reversal using field

 

Type: L2

Offline

 

 

 

 

reversal" function

 

 

 

 

(G200)

0 = binector B0000

 

 

 

 

 

1 = binector B0001

 

 

 

 

 

etc.

 

 

 

 

 

Signal 0: Positive field direction is selected (B0260 = 1, B0261 = 0),

 

 

 

 

actual speed value is not inverted

 

 

 

 

 

Signal 1: Negative field direction is selected (B0260 = 0, B0261 = 1),

 

 

 

 

actual speed value is inverted

 

 

 

 

 

 

 

 

 

 

P581

Source for selection of "Braking with field reversal”

 

All binector numbers

Ind: 2

P052 = 3

*

Selection of binector to control the Braking with field reversal" function

1

FS=0

P051 = 40

BDS

 

Type: L2

Offline

0 = binector B0000

 

 

 

 

 

 

 

 

 

(G200)

1 = binector B0001

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

Signal change 0→1: Reversal of field direction (causes braking);

 

 

 

 

When n<n-min is reached, the original field direction is

 

 

 

 

selected again. The drive switches to state o7.2

 

 

 

P582

Source for selection of "Field reversal”

[SW 1.9 and later]

All binector numbers

Ind: 2

P052 = 3

*

Selection of binector to control "Field reversal" function

 

1

FS=0

P051 = 40

BDS

 

 

Type: L2

off-line

 

 

 

0 = binector B0000

 

 

 

 

 

 

 

 

 

(G200)

1 = binector B0001

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

Signal 0: Positive field direction is selected (B0260 = 1, B0261 = 0)

 

 

 

 

Signal 1: Negative field direction is selected (B0260 = 0, B0261 = 1)

 

 

 

 

 

 

 

 

 

P583

Source for actual speed signal for field reversal logic

 

All connector

Ind: None

P052 = 3

*

 

[SW 1.9 and later]

numbers

FS=167

P051 = 40

 

Selection of connector to be used as actual speed value for the field

1

Type: L2

off-line

 

 

 

 

(G200)

reversal logic.

 

 

 

 

 

0 = binector B0000

 

 

 

 

 

1 = binector B0001

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

10.33 Input quantities for signals

(see also Section 8, Sheet G187 and G188 of Operating Instructions 6RX1700-0AD**)

P590

Source for setpoint of “nset = nact signal 1”

All connector

Ind: None

P052

= 3

*

Setpoint/actual value deviation signal:

numbers

FS=174

P051

= 40

 

1

Type: L2

Offline

(G187)

Selection of connector to be injected as input quantity "nset" for the

 

 

 

 

 

setpoint/actual value deviation signal.

 

 

 

 

 

0 = connector K0000

 

 

 

 

 

1 = connector K0001

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

P591

Source for actual value of "n-set = n-act signal 1"

All connector

Ind: None

P052

= 3

*

Setpoint/actual value deviation signal:

numbers

FS=167

P051

= 40

 

1

Type: L2

Offline

(G187)

Selection of connector to be injected as input quantity "nact" for the

 

 

 

 

 

setpoint/actual value deviation signal.

 

 

 

 

 

0 = connector K0000

 

 

 

 

 

1 = connector K0001

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 