PNU

Description

Value range [Unit] Steps

No. indices Factory setting Type

See Change (Access / Status)

r059

Display of operating state

Meaning as for r000

0.0to 14.5

Ind: None

Type: O2

P052 = 3

10.4Definition of SIMOREG DC MASTER converter

r060

Software version

 

 

 

(G101)

Converter software release

 

 

i001:

CUD

 

 

 

 

 

 

 

 

i002:

Slot D (board location 2)

 

 

i003:

Slot E (board location 2)

 

 

i004:

Slot F (board location 3)

 

 

i005:

Slot G (board location 3)

 

r061

Creation date of software

 

 

(G101)

i001:

Year

 

 

 

i002:

Month

 

 

 

 

 

 

 

 

i003:

Day

 

 

 

 

i004:

Hour

 

 

 

 

i005:

Minute

 

 

 

 

 

 

 

 

 

 

r062

Checksum

 

 

 

 

 

(G101)

i001:

Converter firmware checksum

i002:

Boot sector checksum

 

 

 

 

 

 

 

 

r063

Board code

 

 

 

(G101)

Identification code of boards mounted in locations 1 to 3 of electronics box.

 

 

 

 

 

 

 

 

1

3

2

 

 

 

 

 

 

 

Arrangement of

 

 

 

 

 

 

 

 

 

 

F

D

board locations 1 to 3

 

 

 

 

and slots D to G in

 

 

 

 

 

 

 

 

 

CUDx

 

 

electronics box

 

 

 

 

 

 

 

 

 

 

G

E

 

 

 

 

 

 

 

 

i001: Board in location 1

71:CUD1

72:CUD1 + CUD2

i002: Board in slot D (upper slot of location 2)

111: Pulse encoder board (SBP) [SW 1.8 and later]

131 to 139: Technology board

141 to 149: Communications board

151, 152, 161: Special board (EB1, EB2, SLB)

i003: Board in slot E (lower slot of location 2)

111: Pulse encoder board (SBP) [SW 1.8 and later]

131 to 139: Technology board

141 to 149: Communications board

151, 152, 161: Special board (EB1, EB2, SLB)

i004: Board in slot F (upper slot of location 3)

111: Pulse encoder board (SBP) [SW 1.8 and later]

141 to 149: Communications board

151, 152, 161: Special board (EB1, EB2, SLB)

i005: Board in slot G (lower slot of location 3)

111: Pulse encoder board (SBP) [SW 1.8 and later]

141 to 149: Communications board

151, 152, 161: Special board (EB1, EB2, SLB)

0.0to 9.9

Ind: 5

P052 = 3

Type: O2

 

Ind: 5

P052 = 3

Type: O2

 

Ind: 2

P052 = 3

Type: L2

 

 

 

Ind: 5

P052 = 3

Type: O2

 