Siemens 6RA70 specifications 10-69

Models: 6RA70

1 232
Download 232 pages 59.99 Kb
Page 190
Image 190

PNU

Description

Value range [Unit] Steps

No. indices Factory setting Type

See Change (Access / Status)

P666

2nd source for control word 1, bit7

*(01 transition=acknowledge; ORed with 1st and 3rd sources for bit7)

BDS

(G180)

P667

3rd source for control word 1, bit7

*(01 transition=acknowledge; ORed with 1st and 2nd sources for bit7)

BDS

(G180)

P668

Source for control word 1, bit8

*

(1=inching bit0)

BDS

 

(G180)

 

P669

Source for control word 1, bit9

*

(1=inching bit1)

BDS

 

(G180)

 

P671

Source for control word 1, bit11

*

(0=pos. direction of rotation disabled, 1=pos. direction of rotation enabled)

BDS

 

(G180)

 

P672

Source for control word 1, bit12

*

(0= neg. direction of rotation disabled, 1= neg. direction of rotation enabled)

BDS

 

(G180)

 

P673

Source for control word 1, bit13

*

(1=raise motorized potentiometer)

BDS

 

(G180)

 

P674

Source for control word 1, bit14

*

(1=lower motorized potentiometer)

BDS

 

(G180)

 

P675

Source for control word 1, bit15

*

(0=external fault, 1=no external fault)

BDS

 

(G180)

 

All binector numbers

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=1

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=1

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=1

P051

= 40

 

Type: L2

Offline

 

 

 

 

Control word 2

P676

Source for control word 2, bit16

*

(select function data set bit 0)

BDS

 

(G181)

 

P677

Source for control word 2, bit17

*

(select function data set bit 1)

BDS

 

(G181)

 

P680

Source for control word 2, bit20

*

(select fixed setpoint 0)

BDS

 

(G181)

 

P681

Source for control word 2, bit21

*

(select fixed setpoint 1)

BDS

 

(G181)

 

P684

Source for control word 2, bit24

*

(0=n controller speed droop disabled, 1=enabled)

BDS

 

(G181)

 

P685

Source for control word 2, bit25

*

(0=n controller disabled, 1=n controller enabled)

BDS

 

(G181)

 

P686

Source for control word 2, bit26

*

(0=external fault 2, 1=no external fault 2)

BDS

 

(G181)

 

P687

Source for control word 2, bit27

*

(0=master drive, speed control, 1=slave drive, torque control)

BDS

 

(G181)

 

P688

Source for control word 2, bit28

*

(0=external alarm 1, 1=no external alarm 1)

BDS

 

(G181)

 

All binector numbers

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=1

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=1

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=1

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=0

P051

= 40

 

Type: L2

Offline

All binector numbers

 

 

 

Ind: 2

P052

= 3

1

FS=1

P051

= 40

 

Type: L2

Offline

 

 

 

 

SIEMENS Energy & Automation

10-69

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 190
Image 190