PNU

 

Description

 

 

Value range

No. indices

See

 

 

 

 

 

 

 

 

[Unit]

Factory

Change

 

 

 

 

 

 

 

Steps

setting

(Access /

 

 

 

 

 

 

 

 

Type

Status)

 

Analog input terminals 10 / 11 (analog selectable input 3)

 

 

 

 

 

 

 

 

 

-1000.0 to 1000.0

 

 

 

 

P731

 

Normalization of "Analog selectable input 3"

Ind: 4

P052

= 3

 

 

 

This parameter specifies the percentage value which is generated for an

[%]

FS=100.0

P051

= 40

 

FDS

 

0.1%

Type: I2

Online

 

 

input voltage of 10V (or an input current of 20mA) at the analog input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(G114)

 

The following generally applies:

 

 

 

 

 

 

 

 

For voltage input:

 

 

 

 

 

 

 

 

 

P731 [%] =10 V Y

X .. Input voltage in volts

 

 

 

 

 

 

 

 

 

X

Y .. % value which is generated for input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With current input:

voltage X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P731

[%] = 20 mA Y

X .. Input current in mA

 

 

 

 

 

 

 

 

 

X

Y .. % value which is generated for input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P732

 

Offset for "Analog selectable input 3"

 

-200.00 to 199.99

Ind: None

P052

= 3

 

 

 

 

 

 

[%]

FS=0.00

P051

= 40

 

(G114)

 

 

 

 

0.01%

Type: I2

Online

 

P733

 

Mode of signal injection at "Analog selectable input 3"

 

0 to 3

Ind: None

P052

= 3

*

0 =

Injection of signal with sign

1

FS=0

P051

= 40

 

 

 

 

Type: O2

Offline

 

(G114)

1 =

Injection of absolute value of signal

 

 

 

 

 

 

 

 

 

2 =

Injection of signal with sign, inverted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 =

Injection of absolute value of signal, inverted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P734

 

Source for selection of sign reversal at "Analog selectable input 3"

 

All binector numbers

Ind: None

P052

= 3

*

 

Selection of binector to control sign reversal at the analog input ("1" state

1

FS=0

P051

= 40

 

 

 

 

 

Type: L2

Offline

 

(G114)

 

= reverse sign)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = binector B0000

 

 

 

 

 

 

 

 

 

1 = binector B0001

 

 

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P735

 

Filtering time for "Analog selectable input 3"

 

0 to 10000

Ind: None

P052

= 3

 

 

 

Note: Hardware filtering of approximately 1 ms is applied as standard.

 

[ms]

FS=0

P051

= 40

 

(G114)

 

 

1ms

Type: O2

Online

 

 

 

 

 

 

 

P736

 

Source for enabling of "Analog selectable input 3"

 

All binector numbers

Ind: None

P052

= 3

*

 

Selection of binector to control enabling of the analog input ("1" state =

1

FS=1

P051

= 40

 

 

 

 

 

Type: L2

Offline

 

(G114)

 

enabled)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = binector B0000

 

 

 

 

 

 

 

 

 

1 = binector B0001

 

 

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog input terminals 103 / 104 (main actual value)

 

P741

Normalization for "Main actual value”

-270.00 to 270.00

Ind: 4

P052

= 3

 

FDS

Rated value of input voltage at nmax (=tachometer voltage at maximum

[V]

FS=60.00

P051

= 40

 

0.01V

Type: I2

Online

 

 

speed)

 

 

 

 

 

 

(G113)

This parameter defines the maximum speed when P083=1.

 

 

 

 

 

 

 

 

 

 

 

 

P742

Offset for "Main actual value" analog input

-200.00 to 199.99

Ind: None

P052

= 3

 

 

 

 

[%]

FS=0.00

P051

= 40

 

(G113)

 

 

0.01%

Type: I2

Online

 

P743

Mode of signal injection at "Main actual value" analog input

0 to 3

Ind: None

P052

= 3

 

*

0 =

Injection of signal with sign

1

FS=0

P051

= 40

 

 

 

Type: O2

Offline

 

(G113)

1 =

Injection of absolute value of signal

 

 

 

 

 

 

 

2 =

Injection of signal with sign, inverted

 

 

 

 

 

 

 

 

 

 

 

 

3 =

Injection of absolute value of signal, inverted

 

 

 

 

 

 

 

 

 

 

 

 

P744

Source for selection of sign reversal at "Main actual value" analog

All binector numbers

Ind: None

P052

= 3

 

*

input

 

1

FS=0

P051

= 40

 

(G113)

Selection of binector to control sign reversal at the analog input ("1" state

 

Type: L2

Offline

 

 

 

 

 

 

 

= reverse sign)

 

 

 

 

 

 

0 = binector B0000

 

 

 

 

 

 

1 = binector B0001

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

P745

Filtering time for "Main actual value" analog input

0 to 10000

Ind: None

P052

= 3

 

 

Note: Hardware filtering of approximately 1 ms is applied as standard.

[ms]

FS=0

P051

= 40

 

(G113)

1ms

Type: O2

Online

 

 

 

 

10-74

 

 

SIEMENS Energy & Automation

 

 

 

SIMOREG DC Master Base Drive Panel Operating Instructions

Page 195
Image 195
Siemens 6RA70 specifications 10-74