r653

 

Display of status word 2

 

Ind: None

P052 = 3

 

(G183)

 

Mode of representation on operator panel (PMU):

 

Type: V2

 

 

 

 

 

 

 

 

 

 

 

 

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Segments 0 to 15 correspond to bits 16 to 31 of the status word

Segment ON:

Corresponding bit is in log. "1" state

Segment OFF:

Corresponding bit is in log. "0" state

The following parameters are used to select the binectors (some of which are gated with one another or with other signals) to be applied to the individual bits of the control word.

The settings of all these parameters are as follows:

0 = binector B0000

1 = binector B0001 etc.

The functions and logic operations are also shown on Sheets G180 and G181 in Section 8 of Operating Instructions 6RX1700-0AD**.

Control word 1

P654

Source for control word 1, bit0

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=OFF1, 1=ON; ANDed with terminal 37)

 

 

 

1

FS=1

P051

= 40

BDS

 

 

 

 

Type: L2

Offline

 

 

 

 

 

(G130)

 

 

 

 

 

 

 

 

P655

1st source for control word 1, bit1

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=OFF2; ANDed with 2nd and 3rd sources for bit1)

 

1

FS=1

P051

= 40

 

 

Type: L2

Offline

BDS

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P656

2nd source for control word 1, bit1

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=OFF2; ANDed with 1st and 3rd sources for bit1)

 

1

FS=1

P051

= 40

 

 

Type: L2

Offline

BDS

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P657

3rd source for control word 1, bit1

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=OFF2; ANDed with 1st and 2nd sources for bit1)

 

1

FS=1

P051

= 40

 

 

Type: L2

Offline

BDS

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P658

1st source for control word 1, bit2

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=OFF3=Fast stop; ANDed with 2nd and 3rd sources for bit2)

1

FS=1

P051

= 40

 

Type: L2

Offline

BDS

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P659

2nd source for control word 1, bit2

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=OFF3=Fast stop; ANDed with 1st and 3rd sources for bit2)

1

FS=1

P051

= 40

 

Type: L2

Offline

BDS

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P660

3rd source for control word 1, bit2

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=OFF3=Fast stop; ANDed with 1st and 2nd sources for bit2)

1

FS=1

P051

= 40

 

Type: L2

Offline

BDS

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P661

Source for control word 1, bit3

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=pulse disable, 1=enable; ANDed with terminal 38)

 

1

FS=1

P051

= 40

BDS

 

 

Type: L2

Offline

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P662

Source for control word 1, bit4

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=set ramp-function generator to zero, 1=enable ramp-function generator)

1

FS=1

P051

= 40

BDS

 

Type: L2

Offline

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P663

Source for control word 1, bit5

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=ramp-function generator stop, 1=ramp-function generator start)

1

FS=1

P051

= 40

BDS

 

Type: L2

Offline

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P664

Source for control word 1, bit6

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(0=enable setpoint, 1=disable setpoint)

 

 

 

1

FS=1

P051

= 40

BDS

 

 

 

 

Type: L2

Offline

 

 

 

 

 

(G180)

 

 

 

 

 

 

 

 

P665

1st source for control word 1, bit7

 

 

 

All binector numbers

Ind: 2

P052

= 3

*

(01 transition=acknowledge; ORed with 2

nd

rd

sources for bit7)

1

FS=0

P051

= 40

BDS

 

and 3

 

Type: L2

Offline

(G180)

 

 

 

 

 

 

 

 

10-68

 

 

 

 

SIEMENS Energy & Automation

 

 

 

 

SIMOREG DC Master Base Drive Panel Operating Instructions

Page 189
Image 189
Siemens 6RA70 specifications 10-68