PNU

 

Description

 

Value range

No. indices

See

 

 

 

 

 

 

[Unit]

Factory

Change

 

 

 

 

 

 

Steps

setting

(Access /

 

 

 

 

 

 

 

Type

Status)

 

P641

 

Source for selection of "Bypass ramp-function generator”

 

All binector numbers

Ind: 2

P052 = 3

*

 

Selection of binector to control the "Bypass ramp-function generator"

1

FS=0

P051 = 40

 

BDS

 

 

 

Type: L2

Offline

 

 

function

 

 

 

 

 

 

 

 

 

 

 

 

(G136)

0

= binector B0000

 

 

 

 

 

 

1

= binector B0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

All connector

 

 

 

 

 

 

 

 

 

 

P642

 

Source for variable positive limitation of main setpoint

 

Ind: 4

P052 = 3

*

 

Selection of connectors to be injected at the variable positive limitation of

 

numbers

FS=2

P051 = 40

 

 

 

1

Type: L2

Offline

 

(G135)

 

the main setpoint.

 

 

 

 

 

 

 

The lowest value in each case of the connectors selected via the 4 indices

 

 

 

 

 

 

 

is applied as the limit.

 

 

 

 

 

 

 

Note: Negative values at the selected connectors result in a negative

 

 

 

 

 

 

 

maximum value at the output of the limitation.

 

 

 

 

 

 

0

= connector K0000

 

 

 

 

 

 

1

= connector K0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

P643

 

Source for variable negative limitation of main setpoint

 

All connector

Ind: 4

P052 = 3

*

 

Selection of connectors to be injected at the variable negative limitation of

 

numbers

FS=9

P051 = 40

 

 

 

1

Type: L2

Offline

 

(G135)

 

the main setpoint.

 

 

 

 

 

 

 

The lowest value in each case of the connectors selected via the 4 indices

 

 

 

 

 

 

 

is applied as the limit.

 

 

 

 

 

 

 

Note: Positive values at the selected connectors result in a positive

 

 

 

 

 

 

 

minimum value at the output of the limitation.

 

 

 

 

 

 

0

= connector K0000

 

 

 

 

 

 

...

 

 

 

 

 

 

8

= connector K0008

 

 

 

 

 

 

9

= value as set in parameter P642 (1)

 

 

 

 

 

 

 

10 = connector K0010

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

P644

 

Source for main setpoint

 

All connector

Ind: 4

P052 = 3

*

 

Selection of connector to be injected as the main setpoint

 

numbers

FS=206

P051 = 40

 

FDS

 

1

Type: L2

Offline

 

 

 

 

 

0

= connector K0000

 

 

 

 

 

 

 

 

 

 

 

(G135)

1

= connector K0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

P645

 

Source for additional setpoint

 

All connector

Ind: 4

P052 = 3

*

 

Selection of connector to be injected as an additional setpoint

 

numbers

FS=0

P051 = 40

 

FDS

 

1

Type: L2

Offline

 

 

 

 

 

0

= connector K0000

 

 

 

 

 

 

 

 

 

 

 

(G135)

1

= connector K0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

P646

 

Source for enable signal for ramp-up integrator switchover

 

All binector numbers

Ind: 2

P052 = 3

*

 

Selection of binector to control enabling of the ramp-function integrator

1

FS=1

P051 = 40

 

BDS

 

 

 

Type: L2

Offline

 

 

switchover function.

 

 

 

 

 

 

 

 

 

 

 

 

(G136)

0

= binector B0000

 

 

 

 

 

 

1

= binector B0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

P647

 

Source for enable signal for ramp-function generator tracking

 

All binector numbers

Ind: 2

P052 = 3

*

 

 

[SW 2.1 and later]

1

FS=1

P051 = 40

 

BDS

 

Selection of binector to control enabling of the ramp-function generator

 

 

Type: L2

Offline

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(G136)

 

tracking function.

 

 

 

 

 

0

= binector B0000

 

 

 

 

 

 

 

 

 

 

 

 

1

= binector B0001

 

 

 

 

 

 

 

etc.

 

 

 

 

10-66