Siemens 6RA70 specifications 10-63

Models: 6RA70

1 232
Download 232 pages 59.99 Kb
Page 184
Image 184

 

PNU

 

Description

Value range

No. indices

See

 

 

 

 

 

[Unit]

Factory

Change

 

 

 

 

Steps

setting

(Access /

 

 

 

 

 

Type

Status)

 

P615

 

Source for EMF controller setpoint

All connector

Ind: 4

P052

= 3

*

 

Selection of connectors to be injected as the EMF controller setpoint. The

numbers

FS=

P051

= 40

 

 

 

1

i001: 289

Offline

 

(G165)

connectors selected in the four indices are added.

 

i002: 0

 

 

 

 

 

0 = connector K0000

 

i003: 0

 

 

 

 

 

 

i004: 0

 

 

 

 

 

1 = connector K0001

 

 

 

 

 

 

 

Type: L2

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All connector

 

 

 

 

P616

 

Source for actual EMF controller value

Ind: None

P052

= 3

*

 

Selection of connector to be injected as the actual EMF controller value

numbers

FS=286

P051

= 40

 

(G165)

 

1

Type: L2

Offline

 

 

0 = connector K0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = connector K0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuring of injection of acceleration value

 

 

 

 

 

 

 

 

 

 

 

 

 

P619

 

Source for acceleration injection value

All connector

Ind: None

P052

= 3

*

 

Selection of connector to be applied as the acceleration injection value

numbers

FS=191

P051

= 40

 

 

 

1

Type: L2

Offline

 

(G153)

 

0 = connector K0000

 

 

 

 

 

 

1 = connector K0001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

 

Speed controller

Speed controller, setpoint/actual value deviation

Function:

The connectors selected in parameters P621 and P622 are added and those selected in P623 and 624 subtracted

P620

Source for speed controller setpoint/actual value deviation

*

Selection of connector to be injected as the control deviation

 

(G152)

0 = connector K0000

 

1 = connector K0001

 

etc.

P621

Source for speed controller setpoint

*

0 = connector K0000

 

(G152)

1 = connector K0001

etc.

 

P622

Source for speed controller setpoint

*

0 = connector K0000

 

(G152)

1 = connector K0001

etc.

 

P623

Source for actual speed controller value

*

0 = connector K0000

 

(G152)

1 = connector K0001

etc.

 

P624

Source for actual speed controller value

*

0 = connector K0000

 

(G152)

1 = connector K0001

etc.

 

All connector numbers

1

All connector numbers

1

All connector numbers

1

All connector numbers

1

All connector numbers

1

Ind: None

P052

= 3

FS=165

P051

= 40

Type: L2

Offline

 

 

 

Ind: None

P052

= 3

FS=176

P051

= 40

Type: L2

Offline

 

 

 

Ind: None

P052

= 3

FS=174

P051

= 40

Type: L2

Offline

 

 

 

Ind: None

P052

= 3

FS=179

P051

= 40

Type: L2

Offline

 

 

 

Ind: None

P052

= 3

FS=0

P051

= 40

Type: L2

Offline

 

 

 

Speed controller: Filtering of setpoint and actual value, band-stop filters

P625

Source for speed controller setpoint

*

Selection of connector to be injected as the input signal for speed setpoint

FDS

filtering

 

(G152)

0 = connector K0000

 

1 = connector K0001

 

etc.

 

 

P626

Source for actual speed controller value

*

Selection of connector to be injected as the input signal for actual speed

FDS

value filtering

 

(G152)

0 = connector K0000

 

1 = connector K0001

 

etc.

 

 

All connector numbers

1

All connector numbers

1

Ind: 4

P052

= 3

FS=170

P051

= 40

Type: L2

Offline

Ind: 4

P052

= 3

FS=167

P051

= 40

Type: L2

Offline

SIEMENS Energy & Automation

10-63

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 184