PNU

Description

 

 

Field current monitoring

Value range [Unit] Steps

No. indices

See

Factory

Change

setting

(Access /

Type

Status)

Fault message F005 is activated if the actual field current (K0265) is lower than the percentage of the field current setpoint (K0268) set in P396 for longer than the time set in parameter P397.

Note:

Fault message F005 is only activated, however, if the field current setpoint is > 2% of the converter rated DC current of the field (r073.i02) ist.

P396

Threshold for field current monitoring

[SW 1.9 and later]

1 to 100

Ind: 4

P052

= 3

 

 

 

[%]

FS=50

P051

= 40

FDS

 

 

0.01% of setpoint at

Type: O2

on-line

(G167)

 

 

field current con-

 

 

 

 

 

troller input (K0268)

 

 

 

P397

Field current monitoring time

[SW 1.9 and later]

0.02 to 60.00

Ind: 4

P052

= 3

FDS

 

 

[s]

FS=0.50

P051

= 40

(G167)

 

 

0.01s

Type: O2

on-line

 

 

 

 

 

 

If < If x signal

 

 

 

 

 

P398

Field current threshold If x

 

0.00 to 199.99

Ind: 4

P052

= 3

 

Setpoint-oriented field current threshold for If < If x limit-value monitor.

[%]

FS=80.00

P051

= 40

FDS

0.01% of setpoint at

Type: O2

Online

 

Note:

 

field current

 

 

 

(G188)

 

controller input

 

 

 

This threshold affects the sequence of control operations for the "Direction

 

 

 

 

(K0268)

 

 

 

 

of rotation reversal using field reversal" and "Braking with field reversal"

 

 

 

 

 

 

 

 

 

functions (see Section 9).

 

 

 

 

 

 

The If < If x signal is connected to binector B0216, the actual value at field

 

 

 

 

 

current controller input K0265 is applied as If.

 

 

 

 

 

 

B0216 = 0 when K0265 > threshold set in P398

 

 

 

 

 

 

B0216 = 1 when K0265 < threshold set in P398 + hysteresis set in P399

 

 

 

 

 

0 1 transition takes place when K0265 < P398

 

 

 

 

 

 

1 0 transition takes place when K0265 > P398 + P399

 

 

 

 

 

 

 

0.00 to 100.00

 

 

 

P399

Hysteresis for If < If x signal

 

Ind: 4

P052

= 3

 

This value is added to the response threshold if If < If x

is active.

[%]

FS=1.00

P051

= 40

FDS

0.01% of converter

Type: O2

Online

 

(see also P398)

 

rated field DC

 

 

 

(G188)

 

 

current (r073.i02)

 

 

 

10.19 Settable fixed values

 

 

 

 

 

 

 

 

 

 

 

Function:

The value set in the parameter is applied to the specified connector

 

 

 

 

 

 

 

 

 

 

 

P401

K401 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0401

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P402

K402 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0402

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P403

K403 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0403

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P404

K404 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0404

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P405

K405 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0405

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P406

K406 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0406

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P407

K407 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0407

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P408

K408 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0408

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P409

K409 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0409

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 

P410

K410 fixed value

 

-199.99 to 199.99

Ind: 4

P052

= 3

FDS

is applied to connector K0410

 

[%]

FS=0.00

P051

= 40

(G120)

 

0.01%

Type: I2

Online

 

 