10.29 Friction compensation

(see also Section 8, Sheet G153 of Operating Instructions 6RX1700-0AD**)

Parameters P520 to P530 are the armature current and torque setpoint required for a stationary input signal (factory setting: speed controller actual value K0179) of 0%, 10% to 100% of the maximum value (in steps of 10%).

These parameters are intermediate points along the friction curve. Depending on P170 (0 or 1) they are either an armature current or a torque setpoint and are set automatically when the friction and moment of inertia compensation (P051=28) are optimized. P520 is then set to 0.0%.

The intermediate points are interpolated linearly during which the output of the friction compensation assumes the sign of the input signal. P530 is specified by the friction compensation even for input signals >100% of the maximum signal.

During operation in both directions we recommend leaving P520 at 0.0% in order to avoid armature current vibration at 0% of the input signal.

P519

Source for input signal of the friction compensation [SW 2.0 and later]

All connector

Ind: 2

P052

= 3

*

Selection of the input signals that are added and led to the input of the

numbers

FS=

P051

= 40

 

1

i001: 179

offline

 

friction compensation.

(G153)

 

i002: 0

 

 

 

i001

Input signal, with sign

 

Type: L2

 

 

 

i002

Input signal with absolute value generator

 

 

 

 

 

Settings:

 

 

 

 

 

 

0 = Connector K0000

 

 

 

 

 

1 = Connector K0001

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

 

P520

Friction at 0% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P521

Friction at 10% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P522

Friction at 20% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P523

Friction at 30% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P524

Friction at 40% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P525

Friction at 50% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P526

Friction at 60% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P527

Friction at 70% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P528

Friction at 80% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P529

Friction at 90% speed

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 

P530

Friction at 100% speed and higher

0.0 to 100.0

Ind: 4

P052

= 3

FDS

Setting as % of converter rated DC current or rated torque

[%]

FS=0.0

P051

= 40

0.1%

Type: O2

Online

(G153)

 

 

 

 

 

 

 

 