Siemens 6RA70 specifications Sheet 8 Peer to Peer Interface, Peer-to-peer interface

Models: 6RA70

1 232
Download 232 pages 59.99 Kb
Page 224
Image 224

Siemens Energy & Automation SIMOREG DC Master Base Drive Panel Operating Instructions

11-9

1

2

3

4

5

6

7

8

6RA70 DC MASTER

SIMPLIFIED BLOCK DIAGRAM

(ALL AVAILABLE FUNCTIONS ARE NOT SHOWN ON SIMPLIFIED BLOCK DIAGRAM)

Peer-to-peer interface 2

Enable data send

P817 (1) B

<1>

 

 

G-SST2

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

X172

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

56

 

Tx+

 

 

 

 

 

Receive data

 

r812.01 to .05

 

 

 

r813.01 to .05

Transmit data

 

 

 

 

 

 

 

 

 

 

57

 

Tx-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

every 16Bits

 

P794 (0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

 

Rx+/Tx+

 

 

 

 

 

Word 1

 

 

 

.01

 

 

 

 

 

 

 

 

 

 

K6001

 

K

 

 

Word 1

 

 

 

 

 

 

 

 

.02

 

 

59

 

Rx-/Tx-

 

 

 

 

1

Word 2

 

K6002

 

K

 

 

Word 2

 

 

 

 

 

 

 

.03

 

 

 

 

 

 

 

Word 3

 

K6003

 

K

 

 

Word 3

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

RS485

 

 

 

 

.04

 

 

 

M

 

 

 

0

Word 4

 

K6004

 

K

 

 

Word 4

 

 

 

 

 

 

 

.05

 

 

 

 

 

 

 

 

 

 

Word 5

 

K6005

 

K

 

 

Word 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P795 (0)

P816 (1)

<2>

From preceding

 

 

 

 

 

 

 

To following

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

0

1

0 1

 

 

drive

 

Bit 0

...

Bit 15

 

 

 

drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bus terminator

Enable data receive

 

 

 

B6100

 

B6115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B6200

 

B6215

 

 

 

 

 

 

 

+

M

 

 

 

 

 

 

B6300

 

B6315

 

 

 

 

 

 

 

<1> Binector = 0:

 

 

 

 

B6400

 

B6415

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output drivers are high resistance

 

 

 

B6500

 

B6515

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<2> Binector = 0:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Telegram sign-of-life-monitorig is not active

 

 

 

 

 

 

 

 

 

Parametes for peer-to-peer interface :

 

 

 

 

 

 

 

 

U117 (0)

.01

 

 

 

1 = "Telegram

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P790 (0)

Peer-to-peer On/Off

 

monitoring

 

 

P798 (6030)

Fault signal trip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P797 (0,000s)

Telegram monitoring time

timeout"

B6030

B

1 = "Fault F012"

 

 

 

 

 

 

 

1s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P793 (6)

Baud rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U117 (0)

.16

 

 

P791 (2)

No. of words (1...5)

 

 

B6031

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

r799

Peer-to-peer diagnostic parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

Binector / Connector

 

 

K6020

 

 

 

 

 

Converter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Sheet 8 Peer to Peer Interface ( X172 )

Page 224
Image 224
Siemens 6RA70 specifications Sheet 8 Peer to Peer Interface, Peer-to-peer interface