PNU

 

Description

 

 

Value range

 

No. indices

 

See

 

 

 

 

 

 

 

[Unit]

 

Factory

 

Change

 

 

 

 

 

 

 

Steps

 

setting

 

(Access /

 

 

 

 

 

 

 

 

 

Type

 

Status)

 

P229

 

Control of I component tracking for slave drive

 

 

0 to 1

Ind: 4

P052 = 3

*

0

On a slave drive, the I component of the speed controller is

1

FS=0

P051 = 40

 

FDS

 

 

Type: O2

Offline

 

 

 

made to follow such that M(set, ncontr.) = M(set, limit),

 

 

 

 

 

 

 

 

 

 

 

 

(G152)

 

 

the speed setpoint is set to the actual speed value

 

 

 

 

 

 

 

1

Tracking deactivated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P230

 

Setting period of speed controller integrator

[SW 1.9 and later]

 

0 to 10000

 

Ind: 4

 

P052 = 3

 

 

 

After a positive edge at the binector set in P695, the integrator of the speed

 

[ms]

 

FS=0

 

P051 = 40

 

FDS

 

 

1ms

 

Type: O2

 

on-line

 

 

controller is set to the instantaneous value of the connector set in P631.

 

 

 

 

 

 

 

 

 

 

 

 

 

(G152)

 

If a time of > 0 is set on P230, this setting operation is not performed just

 

 

 

 

 

 

 

 

once, but the speed controller integrator is set continually to the setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

value for the parameterized time period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P234

 

Set speed controller P component to zero

 

 

0 to 1

Ind: 4

P052 = 3

*

0

Set controller P component to zero (i.e. to obtain a pure I

1

FS=1

P051 = 40

 

FDS

 

 

Type: O2

Offline

 

 

 

controller)

 

 

 

 

(G152)

 

 

 

 

 

 

 

 

 

 

1

Controller P component is active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P236

 

Specifying the dynamic response of the speed control loop

 

10 to 100

 

Ind: 4

 

P052 = 3

*

 

 

 

[SW 2.0 and later]

[%]

 

FS=75

 

P051 = 40

 

FDS

 

The parameter value is used as the optimization criterion for the speed

1

 

Type: O2

 

online

 

 

 

 

 

 

 

 

 

 

 

control loop.

 

 

 

 

 

 

 

 

 

 

Note:

 

 

 

 

 

 

 

 

 

 

Changes to this value do not take effect until the speed controller

 

 

 

 

 

 

 

 

 

optimization run (P051 = 26, see Section 7.5) has been executed.

 

 

 

 

 

 

 

 

 

Setting instructions:

 

 

 

 

 

 

 

 

 

-

For drives, for example, with gear backlash, optimization should be

 

 

 

 

 

 

 

 

 

 

started with low dynamic response values (from 10%).

 

 

 

 

 

 

 

 

-

For drives with top synchronism and dynamic response requirements,

 

 

 

 

 

 

 

 

 

 

values up to 100% should be used.

 

 

 

 

 

 

 

10.12 Closed-loop field current control, field gating unit

P250

Alpha G limit (field)

0 to 180

 

Ind: 4

P052

= 3

FDS

Rectifier stability limit for firing angle of field converter

[degrees]

 

FS=0

P051

= 40

(G166)

1 degree

 

Type: O2

Online

 

 

 

P251

Alpha W limit (field)

0 to 180

 

Ind: 4

P052

= 3

FDS

Inverter stability limit for firing angle of field converter

[degrees]

 

FS=180

P051

= 40

(G166)

1 degree

 

Type: O2

Online

 

 

 

P252

Filtering of line frequency correction (field)

0 to 200

 

Ind: 4

P052

= 3

*

The internal line synchronization for the field gating pulses derived from the

[ms]

 

FS=200

P051

= 40

FDS

1ms

 

Type: O2

Offline

field mains infeed terminals is filtered with this time constant. In operation

 

 

 

 

 

 

(G166)

on "weak" power supplies with unstable frequencies, for example, on a

 

 

 

 

 

diesel-driven generator (isolated operation), the filter time constant must be

 

 

 

 

 

 

 

 

 

 

 

 

set lower than for operation on "constant V/Hz" systems in order to achieve

 

 

 

 

 

 

a higher frequency correction speed.

 

 

 

 

 

 

Using the units position, the line synchronization function can be altered

 

 

 

 

 

 

additionally as follows:

 

 

 

 

 

 

When the parameter is set to an uneven number, the measured line zero

 

 

 

 

 

 

crossings for line synchronization are subjected to an extra "filter", may

 

 

 

 

 

 

improve performance in the case of difficulties with brief mains interruptions

 

 

 

 

 

 

(e.g. power supply via sliding current collectors), but may only be set for

 

 

 

 

 

 

constant V/Hz power supplies (not for weak isolated supply systems).

 

 

 

 

 

 

 

 

 

 

 

 

P253

Control word for field precontrol

0 to 1

 

Ind: 4

P052

= 3

*

0

Field precontrol disabled, precontrol output = 180°

1

 

FS=1

P051

= 40

FDS

 

 

Type: O2

Offline

 

 

 

 

1

Field precontrol active, output is dependent on field current

 

 

 

 

 

(G166)

 

 

 

 

 

 

setpoint, field line voltage, P112

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P254

Set field current controller I component to zero

0 to 1

 

Ind: 4

P052

= 3

*

0

Set controller I component to zero (i.e. to obtain pure P

1

 

FS=1

P051

= 40

FDS

 

 

Type: O2

Offline

 

controller)

 

 

(G166)

 

 

 

 

 

 

1

Controller I component is active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P255

Field current controller P gain

0.01 to 100.00

 

Ind: 4

P052

= 3

FDS

This parameter is set automatically during the optimization run for precontrol

0.01

 

FS=5.00

P051

= 40

(G166)

and current controller (armature and field) (P051=25).

 

 

Type: O2

Online

 

 

 

 

 

 

 

 

 

 

 

 