Siemens 6RA70 specifications 10-31

Models: 6RA70

1 232
Download 232 pages 59.99 Kb
Page 152
Image 152

PNU

Description

Value range [Unit] Steps

No. indices Factory setting Type

See Change (Access / Status)

P154

Set armature current controller I component to zero

*

0

Set controller I component to zero (i.e. to obtain pure P

FDS

 

controller)

(G162)

 

1

Controller I component is active

 

 

 

P155

Armature current controller P gain

FDS

Proportional gain of armature current controller

This parameter is automatically set during the optimization run for precontrol

 

(G162)

and current controller (armature and field) (P051=25).

 

 

 

See also parameter P175

 

 

P156

Armature current controller reset time

FDS

This parameter is automatically set during the optimization run for precontrol

and current controller (armature and field) (P051=25).

 

(G162)

See also parameter P176

 

 

P157

Control word for current setpoint integrator

*

0

Reduced gearbox stressing

FDS

 

The integrator is active only after a change in torque direction

(G162)

 

(acts as ramp-function generator for armature current setpoint

 

only until the output reaches the setpoint at the integrator input

 

 

for the 1st time after a change in torque direction).

1Current setpoint integrator

The integrator is always active (acts as ramp-function generator for the armature current setpoint)

P158

Ramp-up time for current setpoint integrator (reduced gearbox

FDS

stressing)

 

 

Period of an acceleration ramp with a setpoint step change from 0% to

 

(G162)

100% at r072.002.

 

For older DC machines (i.e. unsuitable for steep rates of current rise),

 

 

P157=1 and P158=0.040 must be set.

 

 

P159

Switchover threshold for auto-reversing stage (armature)

FDS

 

requested torque direction

(G163)

 

0.05%

 

 

 

I

 

 

 

0

Speed controller output

 

 

 

 

 

II

 

 

 

P159

 

 

 

 

P160

Additional torque-free interval

 

FDS

Additional torque-free interval for torque direction change in 4Q operation.

It is particularly important to set this parameter to values of > 0 for converter

 

(G163)

armatures which supply large inductances (e.g. lifting solenoids).

 

 

P161

Additional Alpha W pulses with disabled second pulses

FDS

Number of additional Alpha W pulses with disabled second pulses after

detection of I=0 message prior to a change in torque direction.

 

(G163)

It is particularly important to set this parameter to values of > 0 for converter

 

armatures which supply large inductances (e.g. lifting solenoids).

 

These pulses cause the current to decay prior to a change in torque

 

direction. When it drops below the thyristor holding current value, the

 

current is suddenly chopped by the unfired second thyristor and the residual

 

energy stored in the load inductor must be dissipated via a suppressor

 

circuit (e.g. a varistor) to prevent the load inductor from producing a surge

 

voltage. See also P179.

 

 

 

P162

EMF calculation method for armature precontrol

*

0

The EMF derived from the measured armature voltage is

FDS

 

applied

 

 

 

 

(G162)

1

The EMF derived from the calculated armature voltage is

 

applied

 

 

 

 

 

 

(the purpose of this setting is to prevent the occurrence of any

 

 

low-frequency (< 15 Hz) armature current fluctuations)

0 to 1

1

0.01to 200.00

0.001 to 10.000 [s]

0.001s

0 to 1

1

0.000 to 1.000 [s]

0.001s

0.00to 100.00

[%]

0.01% of n controller output

0.000 to 2.000 [s]

0.001s

0 to 100

1

0 to 1

1

Ind: 4

P052

= 3

FS=1

P051

= 40

Type: O2

Offline

 

 

 

Ind: 4

P052

= 3

FS=0.10

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=0,200

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=0

P051

= 40

Type: O2

Offline

Ind: 4

P052

= 3

FS=0.000

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=0.01

P051

= 40

Type: O2

Online

Ind: 4

P052

= 3

FS=0.000

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=0

P051

= 40

Type: O2

Online

Ind: 4

P052

= 3

FS=1

P051

= 40

Type: O2

Offline

SIEMENS Energy & Automation

10-31

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 152
Image 152
Siemens 6RA70 specifications 10-31