LED displays

 

 

Run green LED

 

LED illuminated

in “Torque direction active” state (MI, MII, M0).

 

 

(See parameter r000)

Ready yellow LED

 

LED illuminated

in “Ready” state (o1 .. o7).

 

 

(See parameter r000)

Fault red LED

 

LED illuminated

in “Fault signal present” state (o11)

 

 

(See parameter r000)

LED flashing

An alarm is active (see Faults and Alarms).

8.2.2User-friendly operator control panel (OP1S)

The optional, user-friendly, operator control panel with plain text display (order no.: 6SE7090-0XX84-2FK0) can be mounted in the special location provided in the converter door or remotely mounted on the enclosure door. The OP1S connects to the basic converter interface SST1 at sub D connector X300.

Parameters can be selected directly through input of the parameter number by the keyboard of the OP1S. The following interrelationships apply:

 

Displayed

Number to be keyed in

 

number

on OP1S

 

 

 

Basic converter

rxxx, Pxxx

(0)xxx

parameter

Uxxx, nxxx

2xxx

 

Technology board

Hxxx, dxxx

1xxx

 

 

parameter

Lxxx, cxxx

3xxx

 

 

 

 

For more information on the operation of the OP1S, refer to the power module operating instructions and the instructions that were provided with the OP1S.

Siemens Energy & Automation

8-3

SIMOREG DC Master Base Drive Panel

Operating Instructions

Page 72
Image 72
Siemens 6RA70 specifications User-friendly operator control panel OP1S, LED displays