PNU

Description

Value range [Unit] Steps

No. indices Factory setting Type

See Change (Access / Status)

P555

Source for the Influencing quantity of the droop adaptation

*

 

[SW 1.7 and later]

FDS

Selection of which connector is connected at the influencing quantity for

(G151)

adaptation of the n controllers droop

 

0 = Connector K0000

 

 

 

 

1 = Connector K0001

 

 

etc.

 

 

 

 

P556

Adaptation n controller P gain: Threshold 1

 

FDS

 

 

(G151)

 

 

P557

Adaptation n controller integration time: Threshold 1

[SW 1.7 and later]

FDS

 

 

(G151)

 

 

P558

Adaptation n controller droop: Threshold 1

[SW 1.7 and later]

FDS

 

 

(G151)

 

 

P559

Adaptation n controller P gain: Threshold 2

 

FDS

 

 

(G151)

 

 

P560

Adaptation n controller integration time: Threshold 2

[SW 1.7 and later]

FDS

 

 

(G151)

 

 

P561

Adaptation n controller droop: Threshold 2

[SW 1.7 and later]

FDS

 

 

(G151)

 

 

All connector numbers

1

0.00to 100.00

[%]

0.01%

0.00to 100.00

[%]

0.01%

0.00to 100.00

[%]

0.01%

0.00to 100.00

[%]

0.01%

0.00to 100.00

[%]

0.01%

0.00to 100.00

[%]

0.01%

Ind: 4

P052

= 3

FS=0

P051

= 40

Type: L2

off-line

Ind: 4

P052

= 3

FS=0.00

P051

= 40

Type: O2

on-line

Ind: 4

P052

= 3

FS=0.00

P051

= 40

Type: O2

on-line

Ind: 4

P052

= 3

FS=0.00

P051

= 40

Type: O2

on-line

Ind: 4

P052

= 3

FS=0.00

P051

= 40

Type: O2

on-line

Ind: 4

P052

= 3

FS=0.00

P051

= 40

Type: O2

on-line

Ind: 4

P052

= 3

FS=0.00

P051

= 40

Type: O2

on-line

Drehzahlregler - Begrenzung der Statik

P562

Positive speed droop limitation

FDS

 

(G151)

 

P563

Negative speed droop limitation

FDS

 

(G151)

 

0.00to 199.99

[%]

0.01%

-199.99 to 0.00 [%] 0.01%

Ind: 4

P052

= 3

FS=100.00

P051

= 40

Type: O2

Online

Ind: 4

P052

= 3

FS=-100.00

P051

= 40

Type: I2

Online

Speed controller optimization for drives with oscillating mechanical system

On drives with oscillating mechanical components, it can be useful to optimize the speed controller using optimization run P051=29. The frequency response of the controlled system for frequencies from 1 Hz to 100 Hz is recorded during optimization.

The drive is first accelerated up to a base speed (P565, FS=20%). A sinusoidal speed setpoint with low amplitude (P566, FS=1%) is then injected. The frequency of this supplementary setpoint is incremented in 1 Hz steps from 1 Hz up to 100 Hz. An average per frequency is calculated over a parameterizable number of current peaks (P567, FS=300).

P565

Base speed for frequency response recording

[SW 1.9 and later]

 

 

 

P566

Amplitude for frequency response recording

[SW 1.9 and later]

 

 

P567

Number of current peaks for frequency response recording

 

 

[SW 1.9 and later]

 

While the frequency response is being recorded, an average over the

 

number of current peaks set here is calculated for each measuring

 

frequency. High values improve the result, but extend the measuring time.

 

When P567 = 1000, the frequency response recording takes about 9

 

minutes.

 

 

 

 

1.0to 30.0

[%]

0.1%

0.01to 5.00

[%]

0.01%

100 to 1000

1

Ind: None

P052

= 3

FS=20.0

P051

= 40

Type: O2

on-line

Ind: None

P052

= 3

FS=1.00

P051

= 40

Type: O2

on-line

Ind: None

P052

= 3

FS=300

P051

= 40

Type: O2

on-line

 

 

 

SIEMENS Energy & Automation

10-57

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 178