10.47 Visualization parameters: Alarms

r953

Alarm parameter 1

 

 

 

 

 

 

 

Ind: None

P052 = 3

 

Display of active alarms in bit-coded form (A001 to A016).

Type: V2

 

 

 

 

 

If one of the alarms between 1 and 16 is generated, the corresponding

 

 

 

segment in the display lights up.

 

 

 

 

 

 

 

 

16

15

14

13

12

11

10

9

 

 

 

8

7

6

5

4

3

2

1

 

 

See Section 10.2 for meaning of individual alarms.

r954

Alarm parameter 2

 

 

 

 

 

 

 

Ind: None

P052 = 3

 

Display of active alarms in bit-coded form (A017 to A032).

Type: V2

 

 

 

 

 

If one of the alarms between 17 and 32 is generated, the corresponding

 

 

 

segment in the display lights up.

 

 

 

 

 

 

 

 

32

31

30

29

28

27

26

25

 

 

 

24

23

22

21

20

19

18

17

 

 

 

 

 

 

 

 

 

See Section 10.2 for meaning of individual alarms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r955

Alarm parameter 3

 

 

 

 

 

 

 

Ind: None

P052 = 3

 

Parameter alarms 3

 

 

 

 

 

 

 

Type: V2

 

 

 

 

 

 

 

 

 

 

 

 

If one of the alarms between 33 and 48 is generated, the corresponding

 

 

 

segment in the display lights up.

 

 

 

 

 

 

 

 

48

47

46

45

44

43

42

41

 

 

 

40

39

38

37

36

35

34

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r956

Alarm parameter 4

 

 

 

 

 

 

 

Ind: None

P052 = 3

 

Parameter alarms 4

 

 

 

 

 

 

 

Type: V2

 

 

 

 

 

 

 

 

 

 

 

 

If one of the alarms between 49 and 64 is generated, the corresponding

 

 

 

segment in the display lights up.

 

 

 

 

 

 

 

 

64

63

62

61

60

59

58

57

 

 

 

56

55

54

53

52

51

50

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r957

Alarm parameter 5

 

 

 

 

 

 

 

Ind: None

P052 = 3

 

Parameter alarms 5

 

 

 

 

 

 

 

Type: V2

 

 

 

 

 

 

 

 

 

 

 

 

If one of the alarms between 65 and 80 is generated, the corresponding

 

 

 

segment in the display lights up..

 

 

 

 

 

 

 

 

80

79

78

77

76

75

74

73

 

 

 

72

71

70

69

68

67

66

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r958

Alarm parameter 6

 

 

 

 

 

 

 

Ind: None

P052 = 3

 

Parameter alarms 6 (CB alarms)

 

 

 

 

 

Type: V2

 

 

 

 

 

 

 

 

 

 

If one of the alarms between 81 and 96 is generated, the corresponding

 

 

 

segment in the display lights up.

 

 

 

 

 

 

 

 

96

95

94

93

92

91

90

89

 

 

 

88

87

86

85

84

83

82

81

 

 

10-90