PNU

Description

Value range

No. indices

See

 

 

 

[Unit]

Factory

Change

 

 

Steps

setting

(Access /

 

 

 

Type

Status)

P131

Field current for 55% motor flux (field characteristic, point no. 11)

0.0 to 100.0

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=40.6

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P132

Field current for 60% motor flux (field characteristic, point no. 12)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=44.6

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P133

Field current for 65% motor flux (field characteristic, point no. 13)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=48.9

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P134

Field current for 70% motor flux (field characteristic, point no. 14)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=53.6

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P135

Field current for 75% motor flux (field characteristic, point no. 15)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=58.9

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P136

Field current for 80% motor flux (field characteristic, point no. 16)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=64.9

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P137

Field current for 85% motor flux (field characteristic, point no. 17)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=71.8

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P138

Field current for 90% motor flux (field characteristic, point no. 18)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=79.8

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

0.0 to 100.0

 

 

 

P139

Field current for 95% motor flux (field characteristic, point no. 19)

Ind: 4

P052

= 3

FDS

 

[% of P102]

FS=89.1

P051

= 40

(G165)

 

0.1% of P102

Type: O2

Offline

(G166)

 

 

 

 

 

SIEMENS Energy & Automation

10-25

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 146
Image 146
Siemens 6RA70 specifications 10-25