Siemens 6RA70 specifications 10-86, R815 Transmit data on G-SST3

Models: 6RA70

1 232
Download 232 pages 59.99 Kb
Page 207
Image 207

 

PNU

 

Description

Value range

No. indices

See

 

 

 

 

 

[Unit]

Factory

Change

 

 

 

 

 

Steps

setting

(Access /

 

 

 

 

 

 

Type

Status)

 

r814

 

Receive data on G-SST3

 

Ind: 20

P052 = 3

 

 

 

When USS protocol (P800=2) is selected:

 

Type: L2

 

 

(G172)

 

 

 

 

 

 

Display of data received via USS interface 3

 

 

 

 

(G174)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i001:

Display process data word 1

 

 

 

 

 

...

 

 

 

 

 

 

 

i016 Display process data word 16

 

 

 

 

 

 

i017:

Display parameter data word 1

 

 

 

 

 

...

 

 

 

 

 

 

 

i020:

Display parameter data word 4

 

 

 

 

 

 

When peer-to-peer (P800=5) is selected:

 

 

 

 

 

 

Display of data received via peer-to-peer interface 3

 

 

 

 

 

 

i001:

Receive data word 1

 

 

 

 

 

...

 

 

 

 

 

 

 

i005 Receive data word 5

 

 

 

 

 

 

i006:

Not used

 

 

 

 

 

...

 

 

 

 

 

 

 

i020

Not used

 

 

 

 

 

 

 

 

 

 

 

r815

 

Transmit data on G-SST3

 

Ind: 20

P052 = 3

 

 

 

When USS protocol (P800=2) is selected:

 

Type: L2

 

 

(G172)

 

 

 

 

 

 

Display of the data to be transmitted via USS interface 3

 

 

 

 

(G174)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i001:

Display process data word 1

 

 

 

 

 

...

 

 

 

 

 

 

 

i016 Display process data word 16

 

 

 

 

 

 

i017:

Display parameter data word 1

 

 

 

 

 

...

 

 

 

 

 

 

 

i020:

Display parameter data word 4

 

 

 

When peer-to-peer (P800=5) is selected:

Display of the data to be transmitted via peer-to-peer interface 3

i001: Transmit data word 1

...

i005 Transmit data word 5 i006: Not used

...

i020 Not used

Peer-to-peer interfaces: Enable transmission and receipt of telegrams:

If transmission on a peer-to-peer interface is disabled, the associated output drivers are connected to high impedance. If reception is

 

disabled on a peer-to-peer interface, then the telegram failure monitoring function is deactivated.

 

 

 

P816

Peer-to-peer 2: Source for data reception enabling command

All binector numbers

Ind: None

P052

= 3

 

0 = binector B0000

1

FS=1

P051

= 40

(G173)

 

Type: L2

Offline

1 = binector B0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

P817

Peer-to-peer 2: Source for data transmission enabling command

All binector numbers

Ind: None

P052

= 3

 

0 = binector B0000

1

FS=1

P051

= 40

 

 

Type: L2

Offline

(G173)

1 = binector B0001

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

P818

Peer-to-peer 3: Source for data reception enabling command

All binector numbers

Ind: None

P052

= 3

 

0 = binector B0000

1

FS=1

P051

= 40

(G174)

 

Type: L2

Offline

1 = binector B0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

P819

Peer-to-peer 3: Source for data transmission enabling command

All binector numbers

Ind: None

P052

= 3

 

0 = binector B0000

1

FS=1

P051

= 40

(G174)

 

Type: L2

Offline

1 = binector B0001

 

 

 

 

 

 

 

etc.

 

 

 

 

 

 

 

 

 

 

10-86