PNU

Description

Value range [Unit] Steps

No. indices Factory setting Type

See Change (Access / Status)

P604

Source for variable current limit in torque direction II

*

i001..i004Selection of connector to be injected as variable current limit

 

 

 

 

in torque direction II

(G161)

 

 

Normalization: -100% corresponds to P100*P172

 

i005

Selection of connector to be injected as current limit in torque

 

 

 

direction II with Fast Stop or Shutdown

 

 

 

Normalization: -100% corresponds to P100*P172

 

i006

Selection of connector to be injected as variable current limit

 

 

 

in torque direction II

 

 

 

Normalization: -100% corresponds to r072.002

 

 

 

[can be set in SW 1.9 and later]

 

i007

Selection of connector to be injected as current limit in torque

 

 

 

direction II with Emergency Stop or Shutdown

 

 

 

Normalization: -100% corresponds to r072.002

 

 

 

[can be set in SW 1.9 and later]

 

Settings:

 

 

0

= connector K0000

 

...

 

 

 

8

= connector K0008

 

9 = value as set in parameter P603.ixx (1)

 

10

= connector K0010

 

etc.

 

 

 

 

P605

Source for variable positive torque limit

*

Torque limitation:

 

(G160)

Selection of connectors to be injected as the variable positive torque limit

 

 

 

 

i001..i004Normalization:

 

 

 

100% of the connector value corresponds to the positive

 

i005

system torque limit according to Ia=P171 and If = P102

 

Normalization:

 

 

 

100% of the connector value corresponds to the positive

 

 

 

torque limit according to Ia=r072.002 and If = P102

 

 

 

[can be set in SW 1.9 and later]

 

0 = connector K0000

 

1 = connector K0001

 

etc.

 

 

P606

Source for variable negative torque limit

*

Torque limitation:

 

(G160)

Selection of connectors to be injected as the variable negative torque limit

 

 

 

 

i001..i004Normalization:

 

 

 

100% of the connector value corresponds to the negative

 

 

 

system torque limit according to Ia=P172 and If = P102

 

i005

Normalization:

 

 

 

100% of the connector value corresponds to the negative

 

 

 

torque limit according to Ia=r072.002 and If = P102

 

 

 

[can be set in SW 1.9 and later]

 

0

= connector K0000

 

...

 

 

 

8

= connector K0008

 

9

= value as set in parameter P605 (1)

 

10

= connector K0010

 

etc.

 

 

 

 

P607

Source for torque setpoint for master drive

*

Torque limitation:

BDS

Selection of connector to be injected as the torque setpoint for a master

(G160)

drive

 

 

0 = connector K0000

 

 

1 = connector K0001

 

etc.

 

 

 

 

 

 

All connector numbers

1

All connector numbers

1

All connector numbers

1

All connector numbers

1

Ind: 7

P052

= 3

FS=9

P051

= 40

Type: L2

Offline

Ind: 5

P052

= 3

FS=2

P051

= 40

Type: L2

Offline

Ind: 5

P052

= 3

FS=9

P051

= 40

Type: L2

Offline

Ind: 2

P052

= 3

FS=148

P051

= 40

Type: L2

Offline

SIEMENS Energy & Automation

10-61

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 182
Image 182
Siemens 6RA70 10-61, P605 Source for variable positive torque limit, P606 Source for variable negative torque limit