PNU

Description

Value range [Unit] Steps

No. indices Factory setting Type

See Change (Access / Status)

P176

Source for variable Integration time

[SW 1.8 and later]

*

The content of the selected connector acts as the

integration time for the

FDS

armature current controller after multiplication with P156.

(G162)

 

 

P177

Source for the command "no immediate pulse disable"

*

[SW 1.8 and later]

BDS

A low signal causes the armature firing pulses to be disabled immediately

(G163)

without waiting for the I=0 signal or without outputting alpha-W pulses for

current reduction. The additional alpha-W pulses (acc. to parameter P161)

 

 

are not output either. As long as this command is pending, it is not possible

 

to fall below operating state o1.6.

 

This command can be used, for example, if it is not a motor that is supplied

 

by the SIMOREG DC Master but a field and the current is to be reduced via

 

an external parallel-connected de-excitation resistance.

P178

Source for the command "fire all thyristors simultaneously"

*

[SW 1.8 and later]

BDS

Setting this command (high signal) causes all six thyristors of the thyristor

(G163)

bridge I to be fired continuously and simultaneously. Switchover to long

pulses is automatic. This command is only active if no line voltage is applied

 

 

to the armature power section .

P179

Additional Alpha W pulses with disabled second pulses

FDS

[SW 1.9 and later]

Number of additional Alpha W pulses with disabled second pulses after

 

(G163)

detection of I=0 message prior to a change in torque direction.

 

It is particularly important to set this parameter to values of > 0 for converter

 

armatures which supply large inductances (e.g. lifting solenoids).

 

These pulses cause the current to decay before a change in torque

 

direction; the thyristors are fired in pairs to prevent sudden chopping, and

 

the generation of a surge voltage by the load inductor, when the current

 

drops below the thyristor holding current.

 

When a change in torque direction is required, the current in the existing

 

direction must be reduced.

 

This is achieved in the following ways:

 

If P179 > 0:

 

1) Alpha W pulses with enabled second pulses

 

until the I=0 signal arrives

 

2) Additional Alpha W pulses with enabled second pulses

 

(number as set in P179.F)

 

3) Additional Alpha W pulses with disabled second pulses

 

(number as set in P161.F)

 

4) Additional torque-free interval (period as set in P160.F)

 

If P179 = 0:

 

1) Alpha W pulses with disabled second pulses

 

until the I=0 signal arrives

 

2) Additional Alpha W pulses with disabled second pulses

 

(number as set in P161.F)

 

3) Additional torque-free interval (period as set in P160.F)

 

 

P180

Positive torque limit 1

FDS

 

(G160)

 

P181

Negative torque limit 1

FDS

 

(G160)

 

P182

Positive torque limit 2

FDS

If "Torque limit switchover" is selected (state of binector selected in P694

=1) and the speed is higher than the threshold speed set in parameter

 

(G160)

P184, then torque limit 2 is activated in place of torque limit 1.

 

 

P183

Negative torque limit 2

FDS

If "Torque limit switchover" is selected (state of binector selected in P694

=1) and the speed is higher than the threshold speed set in parameter

 

(G160)

P184, then torque limit 2 is activated in place of torque limit 1.

All connector numbers

1

All binector numbers 1

All binector numbers 1

0 to 100

1

-300.00 to 300.00 [%] 0.01%

of rated motor torque

-300.00 to 300.00 [%] 0.01%

of rated motor torque

-300.00 to 300.00 [%] 0.01%

of rated motor torque

-300.00 to 300.00 [%] 0.01%

of rated motor torque

Ind: 4

P052

= 3

FS=1

P051

= 40

Type: L2

off-line

 

 

 

Ind: 2

P052

= 3

FS=1

P051

= 40

Type: L2

off-line

Ind: 2

P052

= 3

FS=0

P051

= 40

Type: L2

off-line

 

 

 

Ind: 4

P052

= 3

FS=0

P051

= 40

Type: O2

on-line

Ind: 4

P052

= 3

FS=300.00

P051

= 40

Type: I2

Online

 

 

 

Ind: 4

P052

= 3

FS=-300.00

P051

= 40

Type: I2

Online

 

 

 

Ind: 4

P052

= 3

FS=300.00

P051

= 40

Type: I2

Online

 

 

 

Ind: 4

P052

= 3

FS=-300.00

P051

= 40

Type: I2

Online

SIEMENS Energy & Automation

10-33

SIMOREG DC Master Base Drive Panel Operating Instructions

 

Page 154
Image 154