Siemens Energy & SIMOREG DC Master

1

2

3

4

5

6

7

8

6RA70 DC MASTER

SIMPLIFIED BLOCK DIAGRAM

(ALL AVAILABLE FUNCTIONS ARE NOT SHOWN ON SIMPLIFIED BLOCK DIAGRAM)

Sheet 6 USS

Automation Base Drive Panel Operating

USS interface 1

X300:

G-SST1

6

+5V

1

 

4

RS232

 

Receive data

r810.17 r810.18

r810.19

r810.20

r811.17 r811.18

r811.19

r811.20

USS parameter data

 

 

 

 

 

Word 1: Param.-ID

 

 

 

 

 

(PKE)

 

 

 

 

 

Word 2: Param.Index

 

 

Parameter

 

 

Word 3: Param.Value

 

 

processing

 

 

 

 

 

 

 

 

Low Word

1

Word 4: Param.Value

High Word

 

Transmit data

USS parameter data

Word 1: Param.-ID (PKE)

Word 2: Param.Index

Word 3: Param.Value

Low Word

Word 4: Param.Value

High Word

Interface 1 ( X300

Instructions

7 TxD

 

 

 

2

RxD

 

 

 

3 Rx+/Tx+

 

 

 

8

Rx-/Tx-

 

 

 

5

M

 

 

RS485

9

M

 

 

 

Submin D

 

 

P785 (0)

 

0

1

0

1

 

 

 

 

Bus terminator

 

 

+

 

M

 

Process data

r810.01 to .16

 

 

 

 

 

 

 

from USS interface

every 16 bits

 

 

 

Word 1

K2001

 

 

 

 

 

Word 2

 

K2002

 

1

Word 3

 

K2003

 

Word 4

 

K2004

 

 

 

 

 

Word 5

 

K2005

 

 

Word 6

 

K2006

 

 

Word 7

 

K2007

 

 

Word 8

 

K2008

 

 

Word 9

 

K2009

 

 

Word 10

 

K2010

 

 

Word 11

 

K2011

 

 

Word 12

 

K2012

 

 

Word 13

 

K2013

 

 

Word 14

 

K2014

 

 

Word 15

 

K2015

 

 

Word 16

 

K2016

 

 

 

 

Bit 0

...

 

 

 

B2100

 

P784

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

Bit 15

B2115

r811.01 to .16

WE .01

32 .02

167 .03

0.04

33 .05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

0.14

0.15

00.16

U116 (0)

Process Data

to USS interface

Word 11 Word 2

Word 3

Word 4

Word 5

Word 6

Word 7

Word 8

Word 9

Word 10

Word 11

Word 12

Word 13

Word 14

Word 15

Word 16

)

Parameters for USS interface

P780

(2)

USS On/Off

P787

(0,000s)

Telegram monitoring time

 

 

B2200

1 = "Telegram

 

B2300

monitoring

 

B2400

timeout"

B2030

 

 

B2500

 

 

B2215

B2315

B2415

B2515

B

.01

11-7

1s

P786 (0)

Slave address

B2600

B2615

U116 (0)

P783

(6)

Baud rate

P781

(2)

Length of process data

P782

(127)

Length of parameter data

r789

 

USS diagnostic parameter

P927

 

Enable parameterization

 

B2031

B2700

 

 

 

 

B2800

 

Fault message trigger

B2900

P788 (2030)

 

 

 

B

1 = "Fault F011"

 

B2715

B2815

B2915

B

.16

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

K2020

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Binector / Connector

 

 

 

 

 

Converter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Page 222
Image 222
Siemens 6RA70 specifications Sheet 6 USS, USS interface, Interface 1