PNU

 

Description

 

 

 

 

 

 

 

 

Value range

No. indices

See

 

 

 

 

 

 

 

 

 

 

 

[Unit]

Factory

Change

 

 

 

 

 

 

 

 

 

 

 

Steps

setting

(Access /

 

 

 

 

 

 

 

 

 

 

 

 

Type

Status)

r040

Display of limitations:

 

 

 

 

 

 

 

 

Ind: None

P052 = 3

 

 

Representation on operator panel (PMU):

 

 

 

 

Type: V2

 

 

 

 

 

 

 

 

 

 

 

 

15

14

13

12

11

10

9

8

 

 

 

 

 

 

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

Segment ON:

Corresponding limitation is reached

 

 

 

 

Segment OFF:

Corresponding limitation is not reached

 

 

Segment or bit

0αW limit (field) reached (P251)

1Negative current limit (field) reached (K0274)

2αW limit (armature) reached (αW acc. to P151

for continuous current, 165° for discontinuous current)

3....... Negative current limit (armature) reached (K0132)

4....... Negative maximum speed reached (P513)

Speed limiting controller responds (B0201)

5....... Negative torque limit reached (B0203)

6....... Neg. limitation at ramp generator output reached (K0182)

7....... Neg. limitation at ramp generator input reached (K0197)

8....... αG limit (field) reached (P250)

9....... Positive current limit (field) reached (K0273)

10....... αG limit (armature) reached (P150)

11....... Positive current limit (armature) reached (K0131)

12....... Positive maximum speed reached (P512)

Speed limiting controller responds (B0201)

13....... Positive torque limit reached (B0202)

14....... Pos. limitation at ramp generator output reached (K0181)

15....... Pos. limitation at ramp generator input reached (K0196)

Note: This parameter has the same bit assignments as connector K0810.

Connector and binector displays

 

 

 

r041

High-resolution connector display:

-200.00 to 199.99

Ind: 2

P052 = 3

 

i001:

Display of connector selected in P042.01

[%]

Type: I2

 

(G121)

0.01%

 

 

i002:

Display of connector selected in P042.02

 

 

 

 

 

 

 

The display value is filtered with a time constant of 300ms (see Section 8,

 

 

 

 

Sheet G121)

 

 

 

 

 

 

 

 

P042

High-resolution connector display:

All connector

Ind: 2

P052 = 3

*

i001:

Selection of connector to be displayed in r041.01

numbers

FS=0

P051 = 40

 

1

Type: L2

Online

(G121)

i002:

Selection of connector to be displayed in r041.02

 

 

 

The display value is filtered with a time constant of 300ms (see Section 8,

 

 

 

 

 

 

 

 

Sheet G121)

 

 

 

 

 

 

 

 

r043

Connector display:

-200.0 to 199.9

Ind: 7

P052 = 3

 

i001:

Display of connector selected in P044.01

[%]

Type: I2

 

(G121)

0.1%

 

 

i002:

Display of connector selected in P044.02

 

 

 

 

 

 

 

i003:

Display of connector selected in P044.03

 

 

 

 

i004:

Display of connector selected in P044.04

 

 

 

 

i005:

Display of connector selected in P044.05

 

 

 

 

i006:

Display of connector selected in P044.06

 

 

 

 

i007:

Display of connector selected in P044.07

 

 

 

 

 

 

 

 

P044

Connector display:

All connector

Ind: 7

P052 = 3

*

i001:

Selection of connector displayed in r043.01

numbers

FS=0

P051 = 40

 

1

Type: L2

Online

(G121)

i002:

Selection of connector displayed in r043.02

 

 

 

i003:

Selection of connector displayed in r043.03

 

 

 

 

 

 

 

 

i004:

Selection of connector displayed in r043.04

 

 

 

 

i005:

Selection of connector displayed in r043.05

 

 

 

 

i006:

Selection of connector displayed in r043.06

 

 

 

 

i007:

Selection of connector displayed in r043.07

 

 

 

 

 

 

 

 

r045

Binector display:

0 to 1

Ind: 4

P052 = 3

(G121)

i001:

Display of binector selected in P046.01

 

Type: O2

 

 

 

 

i002:

Display of binector selected in P046.02

 

 

 

 

 

 

 

 

i003:

Display of binector selected in P046.03

 

 

 

 

i004:

Display of binector selected in P046.04

 

 

 

 

 

 

 

 

 

10-10

 

 

SIEMENS Energy & Automation

 

 

SIMOREG DC Master Base Drive Panel Operating Instructions