PNU

Description

Value range [Unit] Steps

No. indices Factory setting Type

See Change (Access / Status)

P108

Maximum operating speed n3

*

When the speed-dependent current limitation is in use, the maximum speed

FDS

which is defined by the selection of the actual speed source as set in P083,

(G161)

must be entered in this parameter:

 

 

 

When P083=1 (analog tacho):

 

 

Speed at which a tacho voltage as set in P741 is reached

 

When P083=2 (pulse encoder):

 

 

Same value as maximum speed set in P143

 

When P083=3 (operation without tacho):

 

 

Speed at which EMF as set in P115 is reached

 

 

P109

Control word for speed-dependent current limitation

*

0

Speed-dependent current limitation is deactivated

FDS

1

Speed-dependent current limitation is activated

(G161)

 

 

P110

Armature circuit resistance

FDS

This parameter is set automatically during the optimization run for precontrol

(G162)

and current controller (armature and field) (P051=25).

(G165)

 

 

P111

Armature circuit inductance

FDS

This parameter is set automatically during the optimization run for precontrol

(G162)

and current controller (armature and field) (P051=25).

(G165)

 

 

P112

Field circuit resistance

FDS

This parameter is set automatically during the optimization run for precontrol

(G166)

and current controller (armature and field) (P051=25).

 

 

P113

Continuous current factor torque control / current control

*

This parameter defines the current to be permitted as a continuous current

FDS

by the I2t motor monitoring function without activation of alarm message

 

A037 or fault message F037.

 

This current is the product of calculation P113 * P100.

 

 

P114

Thermal time constant of motor

 

(see Section 9.15)

FDS

0.0

I2t monitoring deactivated

P115

EMF at maximum speed in operation without tachometer

FDS

This parameter is used to adjust the speed in cases where the internal

actual EMF value is applied as the actual speed value. P115 defines the

(G151)

EMF which corresponds to maximum speed as a percentage of P078.001.

 

 

P117

Control word for field characteristic

*

0

No valid field characteristic has yet been recorded

FDS

1

Valid field characteristic (P118 to P139 valid)

 

 

The parameter is set automatically during the field-weakening optimization

 

run (P051=27).

 

 

P118

Rated EMF value

FDS

EMF that is reached with a full field (according to parameter P102) and a

speed as set in parameter P119.

(G165)

The parameter is set automatically during the field-weakening optimization

run (P051=27) and specifies in this case the setpoint EMF in the field-

 

weakening range.

 

Note:

 

 

As regards the closed-loop field-weakening control, only the ratio between

 

P118 and P119 is relevant. The EMF setpoint in the field-weakening range

 

is determined by (P101 – P100 * P110). When the setting in P100, P101 or

 

P110 is changed subsequently, the field-weakening optimization run need

 

not be repeated. However, P118 then no longer defines the setpoint EMF in

 

the field-weakening range.

 

When the setting in parameter P102 is changed subsequently, the field-

 

weakening optimization run must be repeated, the same applies if the

 

maximum speed setting is subsequently re-adjusted.

 

 

 

1 to 10000 [rev/min] 1rev/min

0 to 1

1

0.000 to 32.767 []

0.001

0.000 to 327.67 [mH] 0.01mH

0.0to 3276.7

[] 0.1

0.50to 2.00

0.0to 80.0 [min] 0.1min

1.00to 140.00 [% of P078.001] 0.01%

0 to 1

1

0 to 2800 [V]

1V

Ind: 4

P052

= 3

FS=5000

P051

= 40

Type: O2

Offline

Ind: 4

P052

= 3

FS=0

P051

= 40

Type: O2

Offline

 

 

 

Ind: 4

P052

= 3

FS=0.000

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=0.00

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=0.0

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=1.00

P051

= 40

Type: O2

Offline

 

 

 

Ind: 4

P052

= 3

FS=10.0

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=100.00

P051

= 40

Type: O2

Online

 

 

 

Ind: 4

P052

= 3

FS=0

P051

= 40

Type: O2

Offline

 

 

 

Ind: 4

P052

= 3

FS=340

P051

= 40

Type: O2

Offline

SIEMENS Energy & Automation

10-23

SIMOREG DC Master Base Drive Panel Operating Instructions

 