C8051F340/1/2/3/4/5/6/7

2.Absolute Maximum Ratings

Table 2.1. Absolute Maximum Ratings*

Parameter

Conditions

Min

Typ

Max

Units

 

 

 

 

 

 

Ambient temperature under bias

 

–55

 

125

°C

 

 

 

 

 

 

Storage Temperature

 

–65

 

150

°C

 

 

 

 

 

 

Voltage on any Port I/O Pin or /RST with

 

–0.3

 

5.8

V

respect to GND

 

 

 

 

 

 

 

 

 

 

 

Voltage on VDD with respect to GND

 

–0.3

 

4.2

V

 

 

 

 

 

 

Maximum Total current through VDD and

 

 

 

500

mA

GND

 

 

 

 

 

 

 

 

 

 

 

Maximum output current sunk by /RST or any

 

 

 

100

mA

Port pin

 

 

 

 

 

 

 

 

 

 

 

*Note: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the devices at those or any other conditions above those indicated in the operation listings of this specification is not implied. Exposure to maximum rating conditions for extended periods may affect device reliability.