Lucent Technologies 555-230-024 manual Attendant Service

Models: 555-230-024

1 362
Download 362 pages 22.37 Kb
Page 276
Image 276

System Capacity Limits

Table B-2. Maximum System Parameters (Category A/B) — Continued

 

Release 6

 

 

 

 

 

 

ITEM

R6vs

 

R6csi

 

R6si

 

R6r

 

 

 

(16 MB)

 

(16 MB)

 

(16 MB)

 

 

 

 

 

 

 

 

 

 

ARS toll tables

32

 

32

 

32

 

32

 

 

 

 

 

 

 

 

Entries per toll table

800

 

800

 

800

 

800

 

 

 

 

 

 

 

 

Trunk groups in ARS/AAR pattern

6

 

6

 

6

 

16

 

 

 

 

 

 

 

 

UDP (entries)

10000

 

10000

 

10,000

 

50,000

 

 

 

 

 

 

 

 

TOD charts

8

 

8

 

8

 

8

 

 

 

 

 

 

 

 

Toll analysis table entries

1000

 

1000

 

1000

 

1000

 

 

 

 

 

 

 

 

Attendant Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attendant consoles (day:night)11

6:1

 

15:1

 

15:1

 

27:1

Attendant console 100s groups per

20

 

20

 

20

 

20

attendant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attendant control restriction groups

96

 

96

 

96

 

96

 

 

 

 

 

 

 

 

Centralized attendant service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Release link trunks at branch

99/NA

 

99/NA

 

99/NA

 

255/NA

 

 

 

 

 

 

 

 

Release link trunk groups at

1/NA

 

1/NA

 

1/NA

 

1/NA

branch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Release link trunks at main

400/

 

400/

 

400/

 

4000/

 

NA

 

NA

 

NA

 

NA

 

 

 

 

 

 

 

 

Release link trunk groups at

99/NA

 

99/NA

 

99/NA

 

666/NA

main12

 

 

 

 

 

 

 

Other access queues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum number of queues

12

 

12

 

12

 

12

 

 

 

 

 

 

 

 

Maximum number of queue slots13

80

 

80

 

80

 

80

Size range of reserved queue

2-75

 

2-75

 

2-75

 

2-75

 

 

 

 

 

 

 

 

Reserved queue default size

5

 

5

 

5

 

5

 

 

 

 

 

 

 

 

Queue length

80

 

80

 

80

 

300

 

 

 

 

 

 

 

 

Switched loops per console

6

 

6

 

6

 

6

 

 

 

 

 

 

 

 

Authorization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Authorization codes

5000

 

5000

 

5000

 

90,000

 

 

 

 

 

 

 

 

Station security code length

7

 

7

 

7

 

7

 

 

 

 

 

 

 

 

Classes of restriction

96

 

96

 

96

 

96

 

 

 

 

 

 

 

 

Classes of service

16

 

16

 

16

 

16

 

 

 

 

 

 

 

 

Length of authorization code

4-7/NA

 

4-7/NA

 

4-7/NA

 

4-7/NA

 

 

 

 

 

 

 

 

Length of barrier code

4-7/NA

 

4-7/NA

 

4-7/NA

 

4-7/NA

 

 

 

 

 

 

 

 

Length of account codes

1-15

 

1-15

 

1-15

 

1-15

 

 

 

 

 

 

 

 

Restricted call list

1

 

1

 

1

 

1

 

 

 

 

 

 

 

 

Continued on next page

B-6Issue 5 January 1998