Troubleshooting

Aastra Web UI Parameters

Configuration File Parameters

KBD (Keyboard module)

log module kbd

 

 

NET (Network module)

log module net

 

 

PROVIS (Provisioning module)

log module provis

 

 

RTPT (Realtime Transport module)

log module rtpt

 

 

SND (Sound module)

log module snd

 

 

PROF (Profiler module)

log module prof

 

 

XML (Extension Markup Language)

log module xml

 

 

STUN (Simple Traversal of User Datagram Protocol (UDP) through Network

log module stun

Address Translation (NAT)

 

 

 

LLDP (Link Layer Discovery Protocol)

log module lldp

 

 

BLUETOOTH (6739i only)

log module bluetooth

 

 

Setting Values for the Module/Debug Levels

There are 6 debug levels for the modules. Each debug level has a value you can use to turn individual levels ON and OFF. The following table identifies these debug levels and their values. The value of “1” (fatal errors) is the default setting for all modules.

Debug Level

Value

Fatal Errors

1 (default)

 

 

Errors

2

 

 

Warnings

4

 

 

Init

8

 

 

Functions

16

 

 

Info

32

 

 

All debug levels OFF

0

 

 

All Debug Levels ON

65535

 

 

Example 1

To turn two or more debug levels on at the same time, you add the value associated with each level. For example,

Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7

log module linemgr: 7

log module user interface: 7

log module sip: 7

In the above example, fatal errors, general errors, and warnings are logged for the line manager, user interface, and SIP call control modules.

Example 2

Functions and Info = 16 + 32 = 48

log module dis: 48

log module net: 48

log module snd: 48

In the above example, functions and general information are logged for the display drivers, network, and sound mod- ules.

9-3

41-001343-02 REV04 – 05.2014

Page 582
Image 582
Aastra Telecom 41-001343-02 manual Setting Values for the Module/Debug Levels, Log module stun, Debug Level Value