Operational, Basic, and Advanced Parameters

Parameter

Configuration Files

call hold reminder frequency

aastra.cfg, <model>.cfg, <mac>.cfg

 

 

Description

Specifies the time interval, in seconds, between each ring splash sound on the active line. For

 

example, if a call comes into Line 1, and then a call comes into Line 2 and you answer Line 2,

 

Line 1 is automatically placed on hold. While on the active Line 2, after 7 seconds, a ring

 

splash audio sounds on the line reminding you that the call on Line 1 is still on hold (deter-

 

mined by the “call hold reminder timer” parameter), and then the ring splash is heard again

 

after 60 seconds (determined by this parameter).

 

Notes:

 

You must enable the “call hold reminder” and/or “call hold reminder during active calls”

 

parameter(s), and the “call hold reminder timer” parameter, for this parameter to work.

 

A value of “0” prevents additional rings.

 

 

Format

Integer

 

 

Default Value

60

 

 

Range

0-4294967295

 

 

Example

call hold reminder frequency: 50

 

 

Preferred Line and Preferred Line Timeout

Parameter

Configuration Files

preferred line

aastra.cfg, <model>.cfg, <mac>.cfg

 

 

Description

Specifies the preferred line to switch focus to when incoming or outgoing calls end on the

 

phone.

 

 

Format

Integer

 

 

Default Value

1

 

 

Range

0 (none - disables the preferred line focus feature)

 

1-9

 

 

Example

preferred line: 2

 

 

Parameter

Configuration Files

preferred line timeout

aastra.cfg, <model>.cfg, <mac>.cfg

 

 

Description

Specifies the time, in seconds, that the phone switches back to the preferred line after a call

 

(incoming or outgoing) ends on the phone, or after a duration of inactivity on an active line.

 

 

Format

Integer

 

 

Default Value

0 (the phone returns the line to the preferred line immediately)

 

 

Range

0-999

 

 

Example

preferred line timeout: 30

 

 

41-001343-02 REV04 – 05.2014

A-124

Page 723
Image 723