Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series ExaScale.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
6.2.1.1 Introduced on the E-Series.
Usage
Information
This command changes the sampling rate for an interface. By default, the sampling
rate of an interface is set to the same value as the current global default sampling
rate. If the value entered is not a correct power of 2, the command generates an
error message with the previous and next power-of-2 value. Select one of these
two number and re-enter the command.
Related
Commands
sflow sample-rate (Global) — changes the sampling rate globally.
show sflow
Display the current sFlow configuration.
Z9500
Syntax show sflow [interface]
Parameters interface (OPTIONAL) Enter the following keywords and slot/port or
number information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For a Port-Channel Ethernet interface, enter the keyword
port-channel then the slot/port information. The range
is from 1 to 128.
Command
Modes • EXEC
EXEC Privilege
sFlow 1701