Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced the verbose option.
Version 7.7.1.0 Introduced on the S-Series.
Related
Commands offline stack-unit — bring a switch offline to run diagnostic tests.
online stack-unit— reload the system after running offline diagnostic tests.
offline system
Place the switch in the offline state in order to run diagnostic tests.
Z9500
Syntax offline system
Defaults none
Command
Modes
EXEC Privilege
Command
History This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Added a warning message to the off-line diagnostic.
7.7.1.0 Introduced on the S-Series.
Usage
Information To run diagnostic tests on an offline switch, use the diag command.
The system reboots when offline diagnostics complete. This reboot is an automatic
process. A warning message appears when the offline system command is
implemented.
Warning - Diagnostic execution will cause system to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Debugging and Diagnostics 651