Version Description
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Example Dell#clear dampening tegigabitethernet 1/10
Clear dampening counters on TeGi 1/10 [confirm] y
Dell#
Related
Commands show interfaces dampening — displays interface dampening information.
dampening — configures dampening on an interface.
dampening
Configure dampening on an interface.
Z9500
Syntax dampening [[[[half-life] [reuse-threshold]] [suppress-
threshold]] [max-suppress-time]]
Parameters half-life Enter the number of seconds after which the penalty is
decreased. The penalty decreases half after the half-life
period expires. The range is from 1 to 30 seconds. The
default is 5 seconds.
reuse-
threshold
Enter a number as the reuse threshold, the penalty value
below which the interface state is changed to “up”. The
range is from 1 to 20000. The default is 750.
suppress-
threshold
Enter a number as the suppress threshold, the penalty value
above which the interface state is changed to “error
disabled”. The range is from 1 to 20000. The default is 2500.
max-suppress-
time
Enter the maximum number for which a route can be
suppressed. The default is four times the half-life value. The
range is from 1 to 86400. The default is 20 seconds.
Defaults Disabled.
Command
Modes
INTERFACE (conf-if-)
Command
History This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
836 Interfaces