Remote Insight Command Language 287

RIB_INFO Parameter

MODE is a specific string parameter with a maximum length of 10 characters that specifies what you intend to do with the information. Valid arguments are "read" and "write."

Write mode enables both reading and writing of iLO information. Read mode prevents modification of iLO information.

RIB_INFO Runtime Errors

None

RESET_RIB

The RESET_RIB command is used to reset iLO. For this command to parse correctly, the command must appear within a RIB_INFO command block, and RIB_INFO MODE can be set to read or write. The user must have the configure iLO privilege to execute this command.

Example:

<RIBCL VERSION="2.0">

<LOGIN USER_LOGIN="Admin" PASSWORD="Password"> <RIB_INFO MODE = "write">

<RESET_RIB/>

</RIB_INFO> </LOGIN>

</RIBCL>

RESET_RIB Parameters

None

RESET_RIB Runtime Errors

The possible RESET_RIB error message include: