Configuring iLO

35

ProLiant BL p-Class Standard Configuration Parameters

Beginning IP Address (Bay 1)—Assigns the starting IP address. All IP addresses must be valid addresses.

Ending IP Address (Bay 16)—Assigns the ending IP address. All IP addresses must be valid addresses.

Subnet Mask—Assigns the subnet mask for the default gateway. This field may be filled in if either Static IP Bay Configuration or DHCP is enabled. The entire IP address range must conform to the subnet mask.

Gateway IP Address—Assigns the IP address of the network router that connects the Remote Insight subnet to another subnet where the management PC resides. This field may be filled in if either Static IP Bay Configuration or DHCP is enabled.

ProLiant BL p-Class Advanced Configuration Parameters

Domain Name—Enables you to assign the name of the domain in which the iLO will participate.

Primary DNS Server—Assigns a unique DNS server IP address on your network.

Secondary DNS Server—Assigns a unique DNS server IP address on your network.

Tertiary DNS Server—Assigns a unique DNS server IP address on your network.

Primary WINS Server—Assigns a unique WINS server IP address on your network.

Secondary WINS Server—Assigns a unique WINS server IP address on your network.