306 User Guide Integrated Lights-Out

On a ProLiant BL Class server, there is no need for a licensing key. Advanced features are automatically activated.

Example:

<RIBCL VERSION="2.0">

<LOGIN USER_LOGIN="adminname" PASSWORD="password"> <RIB_INFO MODE="write">

<LICENSE>

<ACTIVATE KEY="1111122222333334444455555"/> </LICENSE>

</RIB_INFO> </LOGIN>

</RIBCL>

LICENSE Parameters

ACTIVATE followed by a valid KEY value signals the activation of the iLO advanced pack licensing.

KEY specifies the license key value. The key should be entered as one continuous string. Commas, periods, or other characters should not separate the key value. The key will only accept 25 characters; other characters entered to separate key values will be interpreted as a part of the key and result in the wrong key being entered.

DEACTIVATE signals the deactivation of the iLO advanced pack licensing.

LICENSE Runtime Errors

The possible LICENSE error messages include:

License key error.

License is already active.

User does not have correct privilege for action. CONFIG_ILO_PRIV required.