38 User Guide Integrated Lights-Out

<RIBCL VERSION="2.0">

<LOGIN USER_LOGIN="Admin" PASSWORD="password"> <RIB_INFO MODE="write">

<MOD_NETWORK_SETTINGS> <ENCLOSURE_IP_ENABLE VALUE="Yes"/>

</MOD_NETWORK_SETTINGS> </RIB_INFO>

</LOGIN>

</RIBCL>

Integration with RILOE II Accessory Boards

RILOE II is supported as an option in servers with iLO. Previous generations of the Remote Insight boards, such as the Remote Insight board/PCI and the original RILOE, are not supported in servers with iLO.

iLO firmware detects the presence of RILOE II and automatically disables iLO functionality. Additionally, if iLO firmware detects the presence of the original RILOE, and iLO displays an invalid configuration message.

To re-enable iLO functionality after a RILOE II is removed, use the Security Override Switch and iLO RBSU (on page 22). Select Settings>Enabled for the Enable Lights-Out Functionality (on page 340) setting.