Remote Insight Command Language 319
SET_HOST_POWER Parameters
HOST_POWER enables or disables the Virtual Power Button. The possible values are "Yes" or "No."
SET_HOST_POWER Runtime Errors
The possible SET_HOST_POWER error messages include:
•Server information is open for
•Virtual Power Button feature is not supported on this server.
•Host power is already ON.
•Host power is already OFF.
•User does not have correct privilege for action. RESET_SERVER_PRIV required.
RESET_SERVER
The RESET_SERVER command resets the server if the server is turned on. For this command to parse correctly, the SET_HOST_POWER command must appear within a SERVER_INFO command block, and SERVER_INFO MODE must be set to write.The user must have the virtual power and reset privilege to execute this command.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password"> <SERVER_INFO MODE="write">
<RESET_SERVER/>
</SERVER_INFO> </LOGIN>
</RIBCL>