98 User Guide Integrated Lights-Out

To send a test alert:

1.Select SNMP/Insight Manager Settings in the Administration tab.

2.Click Send Test Alert to generate a test alert and send it to the TCP/IP addresses saved in the SNMP Alert Destination(s) fields.

3.After generating the alert, a confirmation screen is displayed.

4.Check the Insight Manager 7 or Systems Insight Manager console for receipt of the trap.

Configure Insight Manager Integration

iLO enables you to configure the URL (DNS name or IP address) ("Insight Manager Web Agent URL" on page 348) of the Insight Manager Web Agents running on the host server. You can also configure the level of data returned with Insight Manager 7 or Systems Insight Manager identification information.

NOTE: The expected entry in the Insight Manager Web Agent URL field is the IP address or the DNS name only. The protocol (for example, "http://") and a port ID (for example, ":2301") should not be entered.

The link to the Insight Web Agents is found on the blue header bar, next to the Log out link.

Upgrade iLO Firmware

Firmware upgrades enhance the functionality of iLO. The firmware upgrade can be done from any network client using a supported Web browser. Only users with the Update iLO Firmware privilege can upgrade the iLO firmware. The most recent firmware for iLO is available on the HP website.

To upgrade the iLO firmware using a supported Web browser:

1.Log on to iLO using an account that has the Configure iLO Settings privilege.