350 User Guide Integrated Lights-Out
Blade Serial Number

The blade serial number identifies the serial number for the server blade product.

Power Source

The server blade enclosure can be installed in a rack by using one of two configurations:

The server blade power supplies can be used to convert normal AC facility power to 48 V DC to power the rack. In this configuration, select the power source as Rack Provides Power. This setting enables each server blade, enclosure, and power supply to communicate power requirements to ensure proper power consumption without risking power failures.

If the facility can provide 48 V DC power directly, without the need for the provided power supplies, then select Facility Provides 48V. Each server blade will not be required to communicate with the infrastructure for power when powering on or off.

NOTE: It is essential that proper power sizing requirements be performed to ensure sufficient power for all the server blades and other components of the rack.

Enable Automatic Power On

Each server blade can be configured to automatically power on when inserted into the enclosure. Depending on the Power Source setting, the server blade communicates with the rack to determine if enough power is available to power on. If the power is available, then the server blade automatically powers on and begins the normal server booting process.

Enable Rack Alert Logging (IML)

As the server blade receives alerts, these events can be logged to the IML. You can view these events by using the iLO System Status—IML tab. Additional IML viewing tools are available to allow viewing from the installed operating system on the server blade.