Remote Insight Command Language 297

NOTE: If port changes are detected, the iLO management processor will be rebooted to apply the changes after the script has completed successfully.

MIN_PASSWORD command specifies how many characters are required in all user passwords. The value can be from zero to 39 characters.

REMOTE_KEYBOARD_MODEL determines the remote keyboard language translation used during remote console operation. The possible values are:

US

Belgian

British

 

 

 

Danish

Finnish

French

 

 

 

French Canadian

German

Italian

 

 

 

Japanese

Latin American

Portuguese

 

 

 

Spanish

Swedish

Swiss French

 

 

 

Swiss German

 

 

 

 

 

SSH_PORT specifies the port used for SSH connection on iLO. The processor must be reset if this value is changed.

SSH_STATUS determines if SSH is enabled. The valid value are Yes or No, which enables or disables SSH functionality.

SERIAL_CLI_STATUS specifies the status of the CLI. The possible values are:

0—No change

1—Disabled

2—Enabled (no authentication required)

3—Enabled (authentication required)

SERIAL_CLI_SPEED specifies the CLI port speed. The possible values are :

0—No change

1—9,600 bps

2—19,200 bps