<BAY_NAME value="CPQ_Bay_5"/> <FACILITY_PWR_SOURCE value="Yes"/> <RACK_AUTO_PWR value="Yes"/> <LOG_RACK_ALERTS value="Yes"/>

</MOD_BLADE_RACK> </RACK_INFO> </LOGIN>

</RIBCL>

MOD_BLADE_RACK Parameters

All of the following parameters are optional. If a parameter is not specified, then the parameter value for the specified setting is preserved.

RACK_NAME is the name used to logically group together enclosures in a single rack infrastructure. This parameter can be a combination of any printable characters up to a maximum length of 31 characters.

ENCLOSURE_NAME is the name used to logically group together the ProLiant BL Class servers that compose a single enclosure. This parameter can be a combination of any printable characters up to a maximum length of 31 characters.

BAY_NAME is the name used to identifying a particular ProLiant BL class server. This parameter can be a combination of any printable characters up to a maximum length of 31 characters.

FACILITY_PWR_SOURCE determines the source of power for the blade servers. A value of "Yes" directs the server to use facility power and a value of "No" directs the server to use the server blade power supplies.

RACK_AUTO_PWR determines if the blade server should automatically power when inserted into the enclosure. A value of "Yes" causes the blade server to automatically power up and begin normal booting process if power is available. A value of "No" requires the blade server to be manually powered on.