36 User Guide Integrated Lights-Out

Static Route #1, #2, and #3 (destination gateway)—Assigns the appropriate static route destination and gateway IP address on your network (the default IP values are 0.0.0.0 and 0.0.0.0, where the first IP address corresponds to the destination IP, and the second IP address corresponds to the gateway IP).

Enable iLO IP Address Assignment

The bay #1 through bay #16 checkboxes allow you to select which BL p-Class blade servers will be configured. You can Enable All, Clear All, or Apply your selection.

RIBCL RACK_INFO Commands

Several new XML commands have been added to the RIBCL structure to support reading and writing of Static IP Bay Configuration in scripting. The new RIBCL commands must be scripted within a RACK_INFO (on page 310) command block. The new attributes are:

MOD_ENCLOSURE_IP_SETTINGS—Modifies the Static IP Bay Configuration settings. This command is only valid inside a RACK_INFO block. The logged-in user must have the configure iLO privilege. This attribute must appear inside the RACK_INFO command block with MODE = "write."

BAY_ENABLEMASK—Enables the use of Static IP Bay Configuration addressing. The attribute MASK is a 16-bit number. Each bit represents a slot in the enclosure. If the bit is set, that particular slot is assigned to use the Static IP Bay Configuration settings. The LSB represents slot 1. For example, the MASK="0x0001" only allows slot 1 to use Static IP Bay Configuration. This number can be either a hexadecimal number or a decimal number. This command must appear inside the MOD_ENCLOSURE_IP_SETTINGS block.

ENCLOSURE_IP_ENABLE—Enables or disables the use of Static IP Bay Configuration. This attribute must appear inside the MOD_NETWORK_SETTINGS command block. The possible values are "Y" or "N." It is case-insensitive. This attribute is only applicable on blade servers.

Page 36
Image 36
HP Integrated Lights-Out manual Enable iLO IP Address Assignment, Ribcl Rackinfo Commands