Troubleshooting iLO

377

Proxy Server Issues

If the Web browser software is configured to use a proxy server, it will not connect to the iLO IP address. To resolve this issue, configure the browser not to use the proxy server for the IP address of iLO. For example, in Internet Explorer, select Tools, Internet Options, Connections, LAN Settings, Advanced, and then enter the iLO IP address or DNS name in the Exceptions field.

Troubleshooting Alert and Trap Problems

Alert

Explanation

 

 

Test Trap

This trap is generated by a user through the Web configuration page.

 

 

Server Power Outage

Server has lost power.

 

 

Server Reset

Server has been reset.

 

 

Failed Login Attempt

Remote user login attempt failed.

 

 

General Error

This is an error condition that is not predefined by the hard-coded MIB.

 

 

Logs

Circular log has been overrun.

 

 

Security Override Switch

The state of the Security Override Switch has changed (On/Off).

Changed: On/Off

 

 

 

Rack Server Power On

The server was unable to power on because the BL p-Class rack

Failed

indicated that insufficient power was available to power on the server.

 

 

Rack Server Power On

The server was manually forced by the customer to power on despite

Manual Override

the BL p-Class reporting insufficient power.

 

 

Rack Name Changed

The name of the ProLiant BL p-Class rack was changed.

 

 

Inability to Receive Insight Manager 7 or Systems Insight Manager Alarms (SNMP Traps) from iLO

A user with the Configure iLO Settings privilege must connect to iLO to configure SNMP trap parameters. When connected to iLO, be sure that the correct alert types and trap destinations are enabled in the SNMP/Insight Manager Settings screen of the iLO console application.