| Using iLO | 125 |
|
|
|
|
| Feature |
|
|
|
|
|
|
| Language | English |
|
|
|
|
|
| Client/User authentication method | Password |
|
|
|
|
|
| Authentication timeout | 2 minutes |
|
|
|
|
|
| Authentication attempts | 3 |
|
|
|
|
|
| Default SSH port | 22 |
|
|
|
|
|
iLO Shared Network Port
The iLO Shared Network Port enables you to choose either the system NIC or the dedicated iLO NIC for server management. Both regular network traffic and network traffic intended for iLO pass through the system NIC when this feature is selected. The iLO Shared Network Port is only available on a limited number of ProLiant servers, as shown in the “iLO Shared Network Port Requirements (on page 125)” section.
Not all iLO management features are available when using the iLO Shared Network Port. Refer to the “iLO Shared Management Port Features and Restrictions (on page 126)” section for a list of supported and unsupported iLO management features.
iLO Shared Network Port Requirements
The iLO Shared Network Port feature is only available on servers with hardware that supports this feature. In addition to the hardware, both the NIC and iLO firmware must support the feature.
ProLiant Server | Minimum iLO firmware version |
|
|
DL360 G4 | 1.60 |
|
|
DL380 G4 | 1.60 |
|
|
ML370 G4 | 1.60 |
|
|
When using the iLO Shared Network Port, flashing the iLO firmware through the XML interface will take approximately 7 minutes to complete.