Remote Insight Command Language 295

<RIBCL VERSION="2.0">

<LOGIN USER_LOGIN="adminname" PASSWORD="password"> <RIB_INFO MODE="write"> <MOD_GLOBAL_SETTINGS>

<SESSION_TIMEOUT value="60"/> <ILO_FUNCT_ENABLED value="Yes"/> <F8_PROMPT_ENABLED value="Yes"/> <F8_LOGIN_REQUIRED="Y"/> <REMOTE_CONSOLE_PORT_STATUS value="2"/> <REMOTE_CONSOLE_ENCRYPTION value="Y"/> <PASSTHROUGH_CONFIG value=”3”/> <HTTPS_PORT value="443"/>

<HTTP_PORT value="80"/>

<REMOTE_CONSOLE_PORT value="23"/> <TERMINAL_SERVICES_PORT VALUE="3389"/> <VIRTUAL_MEDIA_PORT value="17988"/> <MIN_PASSWORD VALUE="8"/> <REMOTE_KEYBOARD_MODEL VALUE="US"/> <VIRTUAL_MEDIA_PORT value="55"/> <SSH_PORT value="22"/>

<SSH_STATUS value="YES"/> <SERIAL_CLI_STATUS value="3"/> <SERIAL_CLI_SPEED value="1"/>

</MOD_GLOBAL_SETTINGS> </RIB_INFO> </LOGIN>

MOD_GLOBAL_SETTINGS Parameters

All of the following parameters are optional. If a parameter is not specified, then the parameter value for the specified setting is preserved.

SESSION_TIMEOUT determines the maximum session timeout value in minutes. The accepted values are 15, 30, 60 and 120.

ILO_FUNCT_ENABLED determines if the Lights-Out functionality is enabled or disabled for iLO. The possible values are "Yes" or "No." It is case insensitive.

F8_PROMPT_ENABLED determines if the F8 prompt for ROM-based configuration is displayed during POST. The possible values are "Yes" or "No."