Fujitsu V3.1 manual VLAN-Id, Native Vlan, Service Vlan

Models: V3.1

1 362
Download 362 pages 38.53 Kb
Page 175
Image 175

5.4 Wizards

VLAN-Id

The unique VLAN number of the network specified above. The VLAN ID must be assigned uniquely within a shared uplink set.

Native VLAN

Defines a network as native VLAN. All packages that do not contain a VLAN ID will be allowed through this connection.

Service VLAN

Defines a network as service VLAN.

Isolate mode

You activate the isolate mode via Isolate mode. With isolate mode acti- vated, server blades in the same chassis that use the same network can- not communicate with each other, but only with an external device though the uplinks.

This checkbox is not shown if the connection blade does not support iso- late mode.

Add button

Adds the virtual LAN network to the table below.

Table

You can also define a network as a native VLAN or service VLAN and set the isolate mode in the table retrospectively:

Native VLAN

Select the checkbox in the corresponding row under Native VLAN in the table to define a network as a native VLAN.

Service VLAN

Select the checkbox in the corresponding row under Service VLAN in the table to define a network as a service VLAN.

Isolate mode

Select the checkbox in the corresponding row under Isolate mode to set the isolate mode for this network. With isolate mode activated, servers

ServerView Virtual-IO Manager

175

Page 175
Image 175
Fujitsu V3.1 manual VLAN-Id, Native Vlan, Service Vlan