addresses or WWN addresses) are used from now on. Also the boot device priority setting as defined in the VIOM server profile is no longer valid. The performed init boot results in a
Behavior after AC failure
The
1.This PRIMERGY rack server is managed by VIOM.
2.The
3.The unique identification of the VIOM installation.
4.The SNMP trap destination as specified by VIOM when managing the server.
5.Whether VIOM virtualization data was stored in the iRMC before power loss or not.
If VIOM virtualization data was stored in the iRMC before power loss and because the iRMC knows that the server was managed by VIOM and that vir- tualization data was assigned, a special communication process with the VIOM management station will start when the iRMC is booted again after power has returned. This communication is based on sending SNMP traps to the VIOM management station and setting specific status information in the iRMC. For this process to work, the VIOM management station must be run- ning and must be accessible to the iRMC.
As long as the iRMC did not receive virtualization data from the VIOM man- agement station, it will periodically send SNMP traps to the management