*JOULE HEAT FRACTION
10.5 *JOULE HEATFRACTION: Define the fraction of electric energy released as heat.
This option is used tospecify the fraction of dissipated electrical energy released as heat in coupled thermal-
electrical problems.
Product: ABAQUS/Standard
Type: Model data
Level: Model
Reference:
“Coupled thermal-electrical analysis,” Section6.6.2 of the ABAQUS Analysis User ’sManual
There are no parameters associated with this option.
Data line to define the joule heat fraction:
First (and only) line:
1. Fractionof electrical energy released as heat, including any unit conversionfactor. Thedefault
value is 1.0.
10.5–1
ABAQUS Version 6.1 Module: ID: