*STEADY STATE DETECTION
18.33 *STEADY STATE DETECTION: Specify steady-state requirements for terminating a
quasi-static uni-directional simulation.
This option is used to define the conditions that must be satisfied to determine that steady state ha s been
reached. It must be used in conjunction with the *STEADY STATECRITERIA option.
Product: ABAQUS/Explicit
Type: History data
Level: Step
References:
“Steady-state detection,” Section11.8.1 of the ABAQUS Analysis User’s Manual
“Output to the output database,” Section 4.1.3 of the ABAQUS Analysis User ’sManual
*STEADY STATECRITERIA
Required parameters:
ELSET
Setthis parameter equal to the name of the element set for which this steady-state detection definition
is being applied.
SAMPLING
This parameter is used to specify the method used to sample all steady-state norms associated with
this option. See “Steady-state detection,” Section 11.8.1of the ABAQUS Analysis User ’sManual,
for more information regarding steady-state norm defini tions.
Set SAMPLING=PLANE BY PLANE to calculate the steady-state norms as each plane of
elements crosses the exit plane. This method should be used only for non-Eulerian analyses with
uniform planes of elements sequentially passing the exit plane.
Set SAMPLING=UNIFORM to calculate the steady-state norms at an interval definedby the
time required form aterialto flow through an element of average length. Thisinterval is determined
at the beginning of the step and remains constant throughout the step. Thismethod should be used
only for analyses with material flowing in and out of Eulerian boundary regions in the primary
direction.
Data line to define primary direction and cutting plane position:
First (and only) line:
1. First direction cosine of primary direction.
2. Seconddirection cosine of primary direction.